background image

owner’s manual 

2

In order to avoid electric shock or fire, make sure that an 
earth leak detector is installed.

Be sure the air conditioner is grounded.

 

In  order  to  avoid  electric  shock,  make  sure  that  the  unit  is 
grounded  and  that  the  earth  wire  is  not  connected  to  gas  or 
water pipe, lightning conductor or telephone earth wire.

In  order  to  avoid  injury,  do  not  remove  the  fan  guard  of 
the outdoor unit.

Do not operate the air conditioner if wet. 

An electric shock may occur. 

Do not touch the heat exchanger fins. 

These fins are sharp and could result in cutting injuries.

Do not place items which might be damaged by moisture 
under the indoor unit. 

Condensation  may  form  if  the  humidity  is  above  80%,  the 
drain outlet is blocked or the filter is polluted. 

After  a  long  use,  check  the  unit  stand  and  fitting  for 
damage.

 

If damaged, the unit may fall and result in injury.

To  avoid  oxygen  deficiency,  ventilate  the  room 
sufficiently  if  equipment  with  burner  is  used  together 
with the air conditioner.

Arrange the drain hose to ensure smooth drainage.

Incomplete  drainage  may  cause  water  damage  to  the 
building, furniture etc.

Never touch the internal parts of the controller.

 

Do  not  remove  the  front  panel.  Some  parts  inside  are 
dangerous to touch, and machine breakdown may occur.

Never expose little children, plants or animals directly to 
the air flow. 

Adverse  influence  to  little  children,  animals  and  plants  may 
result.

Do not allow children to play on the outdoor unit or avoid 
placing any object on it.

 

Falling may result in injury.

Do  not  operate  the  air  conditioner  when  using  a  room 
fumigation - type insecticide. 

Failure  to  observe  could  cause  the  chemicals  to  become 
deposited  in  the  unit,  which  could  endanger  the  health  of 
those who are hypersensitive to chemicals.

Do  not  place  appliances  which  produce  open  fire  in 
places exposed to the air flow from the unit or under the 
indoor unit.

 

It  may  cause  incomplete  combustion  or  deformation  of  the 
unit due to the heat.

Do  not  install  the  air  conditioner  at  any  place  where 
flammable gas may leak out. 

If  the  gas  leaks  out  and  stays  around  the  air  conditioner,  a 
fire may break out. 

The appliance is not intended for use by young children 
or infirm persons without supervision.

2.    PARTS NAMES

■ 

  Four-way cassette type 

Air Out Louver (Adjustable)

Lock buckle 
(For closing the Air Grille)

Air Intake 
(Intake air from here)

Air Filter
 (Filter the dust in the intake air)

Grounding Screw  
(In the control box) 

Two-direction or Three-direction Air  
Outlet For the detailed information  
please consult your local dealer. 

■ 

  Ceiling-floor type 

Air Outlet Horizontal Louver 

Air Intake 
(Intake room air)

Air Filter 
(Filter the dust in the air) 

Air Filter (Filter the dust in the intake air)

Air Out Horizontal Louver 
(Adjust air-out direction) 

Grounding Screw 
(In the control box) 

Air Intake

■ 

  One-way cassette type 

Fig.2-1 

Fig.2-2 

Fig.2-3 

NOTE 

All the pictures in this manual are for explanation purpose only. 
They may be slightly different from the air conditioner you 
purchased(depend on model). The actual shape shall prevail. 

Содержание VRF series

Страница 1: ...SYSVRF Indoor unit VRF Indoor units OWNER MANUAL GB...

Страница 2: ...egarding the connection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the ground water and get into the food chain damaging your h...

Страница 3: ...llow children to play on the outdoor unit or avoid placing any object on it Falling may result in injury Do not operate the air conditioner when using a room fumigation type insecticide Failure to obs...

Страница 4: ...dust in the intake air Grounding Screw In the control box Air Intake Air Out Air Out Louver Adjust the air Aout direction Fig 2 4 Fig 2 7 Fig 2 8 Fig 2 9 Air return grille Induced air decoration Dust...

Страница 5: ...let pipe Electric control box Fig 2 10 Fig 2 11 Fig 2 12 Fig 2 14 4 Low static pressure type Air Outlet Connect the duct Grounding Screw In the control box Control Box Air Intake Intake room air Air F...

Страница 6: ...and effective operation The Max operation temperature for the air conditioner Cooling Heating 3 AIR CONDITIONER OPERATIONS AND PERFORMANCE Cooling operation Heating operating cooling only type withou...

Страница 7: ...the difference of the room temperature The louver direction Choose horizontal outlet mode when cooling operation When the cooling operation the air flow down will cause condensing dew on the air outle...

Страница 8: ...down when the air flow is down Horizontal louver Less than 40 2 The slant angle of horizontal louver must be Less than 40 otherwise condensation drops may occur vertical louver vertical louver When ad...

Страница 9: ...he horizontal louver with hands or malfunction may occur Adjust it with the swing button on the wire controller 1 2 3 Ceiling floor type Auto swing Press SWING button the louver will swing up and down...

Страница 10: ...attern depending on the operating mode situation During Dry mode so that cold air does not come into direct contact with people air is blown upper air outlet Regardless of the operating mode or situat...

Страница 11: ...se If the air conditioner is positioned in a dusty place the cleaning frequency of the air filter must be increased If the accumulated dust is too heavy to be cleaned please replace the filter with a...

Страница 12: ...in version I proceed as followed Fig 5 9 Fig 5 10 Take off the inlet grille from the panel Air Outlet Selection Switch special function filter For Console Type Push the grille switches to the arrow d...

Страница 13: ...e Fig 5 15 Fig 5 16 12 owner s manual Inlet grille According to the figure shown in the position and direction of arrow press the filter and take it down In the same way take down the filter on the ot...

Страница 14: ...top or flow change A continuous low hissing sound is heard when the system is in cooling operation or at a stop When the drain pump optional accessories is in operation this noise is heard A squeaking...

Страница 15: ...Doors and windows are open Direct sunlight Too much heat resource Outdoor temp is too high Leakage of refrigerant or lack of refrigerant Wait for the comeback of power Switch on the power Replace the...

Страница 16: ...signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse of time Check whether the timer operation has come to an end wh...

Страница 17: ...alfunctions disappear it restores automatically When the indoor unit is replaced with a correct one or is turned off the alarm will disappear Table 7 4 NO Type Contents Display content Remarks Room te...

Страница 18: ...SYSVRF indoor units_OM EN April 2014 202000191029 WP MDV03U 011PW...

Отзывы: