background image

Declaration of Conformity |

1

1

Declaration of Conformity

Manufacturer

Systemair Sverige AB
Industrivägen 3
SE-739 30 Skinnskatteberg SWEDEN
Office: +46 222 440 00
www.systemair.com

hereby confirms that the following products:

Cooling unit

Topvex SoftCooler TR09

Topvex SoftCooler TR12

Topvex SoftCooler TR15

(The declaration applies only to product in the condition it
was delivered in and installed in the facility in accordance
with the included installation instructions. The insurance
does not cover components that are added or actions
carried out subsequently on the product).

Comply with all applicable requirements in the following
directives and regulations

Machinery Directive 2006/42/EC

Low Voltage Directive 2014/35/EU

EMC Directive 2014/30/EU

Pressure Equipment Directive (PED) 2014/68/EU

Ecodesign Directive 2009/125/EC

327/2011 Requirements for fans
1253/2014 Requirements for ventilation units

The following harmonized standards are applied in ap-
plicable parts:

EN ISO 12100

Safety of machinery - General principles for design - Risk
assessment and risk reduction.

EN 13857

Safety of machinery – Safety distances to prevent hazard
zones being reached by upper or lower limbs.

EN 60204-1

Safety of machinery – Electrical equipment of machines –
Part 1: General requirements.

EN 60335-1

Household and similar electrical appliances – Safety Part
1: General requirements.

EN 60335-2-40

Safety of household and similar electrical appliances -
Part 2-40: Particular requirements for electrical heat
pumps, air-conditioners and dehumidifiers.

EN 50106

Safety of household and similar electrical appliances –
Particular rules for routine tests referring to appliances
under the scope of EN 60 335-1.

EN 13053

Ventilation for buildings – Air handling units – Rating and
performance for units, components and sections.

EN 60529

Degrees of protection provided by enclosures (IP Code).

EN 62233

Measurement methods for electromagnetic fields of
household appliances and similar apparatus with regard
to human exposure.

EN 61000-6-2

Electromagnetic compatibility (EMC) – Part 6-2: Generic
standards – Immunity for industrial environments.

EN 61000-6-3

Electromagnetic compatibility (EMC) – Part 6-3: Generic
standards – Emission standards for residential, commer-
cial and light-industrial environments.

EN 378-2:2016

Refrigerating systems and heat pumps – Safety and envi-
ronmental requirements – Part 2: Design, construction,
testing, marking and documentation.

The complete technical documentation is available.

Skinnskatteberg, 27-01-2020

Sofia Rask
Managing Director

208767 | A006

Содержание Topvex TR 09 Series

Страница 1: ...Document in original language 208767 A006 Topvex SoftCooler TR09 15 Access control system Installation instructions GB...

Страница 2: ...208767 A006...

Страница 3: ...ing the unit 7 6 4 Dividing the Topvex TR air handling unit 9 6 5 Duct connections 11 6 6 Condensation and Heat Insulation 11 6 7 Condensation drain 12 6 8 Electrical connection 12 7 Function Descript...

Страница 4: ......

Страница 5: ...er or lower limbs EN 60204 1 Safety of machinery Electrical equipment of machines Part 1 General requirements EN 60335 1 Household and similar electrical appliances Safety Part 1 General requirements...

Страница 6: ...ape well Duct connections duct ends should be covered during storage and installation Do not connect tumble dryers to the ventilation system 3 Refrigerant Control Reporting Topvex SoftCooler TR comes...

Страница 7: ...ig 1 Dimensions mm TR09 TR15 Drawn as left hand unit Model AA B C D E F G I J K L TR09 2630 1630 1120 810 895 104 129 129 105 210 700 TR12 2770 1740 1230 930 965 76 104 104 105 215 800 TR15 2820 1980...

Страница 8: ...9230 20 5 5 4 3 Components Fig 2 Connections and basic components in left hand connected units Position Description 1 Compressor 2 Condenser coil 3 Evaporator coil 4 Filter drier with sight glass 5 E...

Страница 9: ...7 8 Fig 3 Electrical cabinet Position Description 1 Terminal block mains supply 2 Circuit breaker MCB oil heaters 3 Relays 4 Terminal block internal external connections 5 Frequency converter with dis...

Страница 10: ...here how to install Topvex SoftCooler are meant for indoor installation Place the unit on a horizontal flat surface It s important that the unit is completely levelled before it is put into operation...

Страница 11: ...Installation without by pass left hand unit Position Description Supply air Exhaust air Outdoor air Extract air 1 VAV Pressure transmitters accessory 2 Damper and motor outdoor air accessory 3 Damper...

Страница 12: ...tion Description Supply air Exhaust air Outdoor air Extract air 1 Exhaust air By pass 2 VAV Pressure transmitters accessory 3 Damper and motor outdoor air accessory 4 Damper and motor exhaust air acce...

Страница 13: ...it casing directly to the elec trical connection box See enclosed wiring diagram and chapter 6 8 1 table 2 for more information Warning The units electrical connection to the mains power supply must b...

Страница 14: ...10 Installation A Fig 6 Illustration shows the left handed version of the unit 208767 A006...

Страница 15: ...ct connections on top of the unit Outdoor air Supply air Extract air and 2 Exhaust air Duct connections can be done on two different ways with or without a by pass function for the exhaust air For duc...

Страница 16: ...SoftCooler Use the included plastic connection pipe which is to be cut to the correct height H according to the below figure See the below table for the relation of hight H and maximum under pressure...

Страница 17: ...al block Description Remark PE Ground 400V 3N 50Hz supplied via safety switch N N Earthed neutral supply voltage L1 L1 Phase supply voltage L2 L2 Phase supply voltage L3 L3 Phase supply voltage 28 G B...

Страница 18: ...Fig 11 With by pass left hand unit Position Description EF Extract air fan SF Supply air fan SS Temp sensor supply air OS Temp sensor outdoor air ETS Temp sensor extract air UC Control unit RC Rotor...

Страница 19: ...ssor CPR are step less controlled between in the frequency converter FC set minimum and maximum frequency 7 4 Power limitation The frequency converter FC is continuously sensing the condensing pressur...

Страница 20: ...chapter 6 8 1 External Internal connections Internal operating cable connected see chapter 6 8 1 External Internal connections The two transparent pressure measuring tubes to the extract fan connected...

Страница 21: ...ply and extract fan via the Topvex air handling units safety switch Turn on the mains supply for the Topvex SoftCooler via the working switch make sure that the voltage is on the display in the freque...

Страница 22: ...the Topvex SoftCooler be closed for at least 5 minutes before reading Output frequency Param d001 Output current Param d002 Condenser pressure Param d004 Output frequency __________________Hz Output c...

Страница 23: ...208767 A006...

Страница 24: ...ler TR09 15Access control system Installation instructions 208767 en_GB 2020 01 27 A006 Systemair Sverige AB Industriv gen 3 SE 739 30 Skinnskatteberg Sweden Phone 46 222 440 00 Fax 46 222 440 99 www...

Отзывы: