1 Declaration of Conformity

Manufacturer

Systemair Sverige AB
Industrivägen 3
SE-739 30 Skinnskatteberg SWEDEN
Office: +46 222 440 00 Fax: +46 222 440 99
www.systemair.com

hereby confirms that the following products:

Cooling unit

Topvex SoftCooler TR09

Topvex SoftCooler TR12

Topvex SoftCooler TR15

(The declaration applies only to product in the condition it was delivered in and installed in the facility in accordance
with the included installation instructions. The insurance does not cover components that are added or actions
carried out subsequently on the product)

Comply with all applicable requirements in the following directives and regulations

Machinery Directive 2006/42/EC

Low Voltage Directive 2014/35/EU

EMC Directive 2014/30/EU

Ecodesign Directive 2009/125/EC

327/2011 Requirements for fans
1253/2014 Requirements for ventilation units

The following harmonized standards are applied in applicable parts:

EN ISO 12100:2010

Safety of machinery - General principles for design - Risk assessment and risk reduction

EN 13857

Safety of machinery – Safety distances to prevent hazard zones being reached by
upper or lower limbs

EN 60204-1

Safety of machinery – Electrical equipment of machines – Part 1: General requirements

EN 60335-1

Household and similar electrical appliances – Safety Part 1: General requirements

EN 60335-2-40

Safety of household and similar electrical appliances - Part 2-40: Particular requirements
for electrical heat pumps, air-conditioners and dehumidifiers

EN 50106:2007

Safety of household and similar appliances – Particular rules for routine tests referring to
appliances under the scope of EN 60 335-1 and EN 60967

EN 60529

Degrees of protection provided by enclosures (IP Code)

EN 62233

Measurement methods for electromagnetic fields of household appliances and similar
apparatus with regard to human exposure

EN 61000-6-2

Electromagnetic compatibility (EMC) – Part 6-2: Generic standards – Immunity for
industrial environments

EN 61000-6-3

Electromagnetic compatibility (EMC) – Part 6-3: Generic standards – Emission
standards for residential, commercial and light-industrial environments

The complete technical documentation is available.

Skinnskatteberg, 15-03-2016

Mats Sándor
Technical Director

Topvex SoftCooler TR09-15

Installation instructions

208767

1

Systemair Sverige AB

Содержание Topvex SoftCooler TR Series

Страница 1: ...Topvex SoftCooler TR09 15 Installation instructions Document in original language 208767 EN_GB 15 03 2016 A004...

Страница 2: ...here how to install 7 6 3 Installing the unit 8 6 3 1 Installation 8 6 3 2 Installation procedure 10 6 4 Dividing the Topvex TR air handling unit 11 6 4 1 Assembly the Topvex SoftCooler 12 6 4 2 Elect...

Страница 3: ...inery Safety distances to prevent hazard zones being reached by upper or lower limbs EN 60204 1 Safety of machinery Electrical equipment of machines Part 1 General requirements EN 60335 1 Household an...

Страница 4: ...arm water and wash for 20 minutes visit a doctor The units electrical connection to the mains supply must be preceded by an all pole circuit breaker with a minimum 3 mm gap Caution If the unit is inst...

Страница 5: ...ic information and recommendations concerning the design installation start up and operation to ensure a proper fail free operation of the unit The key to proper and safe operating of the unit is to r...

Страница 6: ...105 210 700 TR12 2770 1740 1230 930 965 76 104 104 105 215 800 TR15 2820 1980 1470 1180 965 76 104 104 105 236 1000 Model M N O P Q R S Weight kg Total Weight kg1 TR09 300 190 1030 870 840 550 120 26...

Страница 7: ...hand connected units Position Description 1 Compressor 2 Condenser coil 3 Evaporator coil 4 Filter drier with sight glass 5 Expansion valve 6 Drip tray with drain 7 Water seal 8 Cable grommet for exte...

Страница 8: ...rminal block mains supply 2 Circuit breaker MCB oil heaters 3 Relays 4 Terminal block internal external connections 5 Frequency converter with display 6 DC Choke 7 Transformer 24 V 8 Display Topvex So...

Страница 9: ...or indoor installation Place the unit on a horizontal flat surface It s important that the unit is completely levelled before it is put into operation The electronic components should not be exposed t...

Страница 10: ...t Position Description Supply air Exhaust air Outdoor air Extract air 1 VAV Pressure transmitters accessory 2 Damper and motor outdoor air accessory 3 Damper and motor exhaust air accessory 4 Locked c...

Страница 11: ...door air Extract air 1 Exhaust air By pass 2 VAV Pressure transmitters accessory 3 Damper and motor outdoor air accessory 4 Damper and motor exhaust air accessory 5 Damper and motor exhaust air by pas...

Страница 12: ...aker safety switch which is enclosed inside the unit on delivery The wiring between the safety switch and the unit is led through the top of the unit casing directly to the electrical connection box S...

Страница 13: ...plit the unit Remove the heat exchanger extract fan and the extract air filter A Remove the plate B Loose the cable connectors C Remove the 7 M10 screws that join the two halves of the appliance Fig 6...

Страница 14: ...ex SoftCooler have been joined together with the two air handling unit parts it is in total 5 duct connections on top of the unit Outdoor air Supply air Extract air and 2 Exhaust air Duct connections...

Страница 15: ...ing The unit is not to be taken into operation before the included condensation drain and water seal are connected from the Topvex SoftCooler to the floor drain The drain is to be connected to the dra...

Страница 16: ...ee also the chapter Internal electrical connections 3 Move the Exhaust air temp sensor EHS located at the extract air filter from its place to the new place by the label EHS in the SoftCooler Fig 10 E...

Страница 17: ...tion Remark G G 24V AC 4 DI ref Referens 10 DO ref Referens 12 DO Exhaust air damper A signal from control unit E28 is lead via the relay R2 to terminal 28 for controlling of the by pass damper access...

Страница 18: ...Description EF Extract air fan SF Supply air fan SS Temp sensor supply air OS Temp sensor outdoor air ETS Temp sensor extract air EHS Temp sensor exhaust air UC Controller E28 RC Rotor control RM Rot...

Страница 19: ...3 Power control The compressor CPR are step less controlled between in the frequency converter FC set minimum and maximum frequency 7 4 Power limitation The frequency converter FC is continuously sens...

Страница 20: ...nected via the Safety switch see chapter 6 4 2 Electrical connection By pass damper connected when such is to be used accessory see chapter 6 4 2 1 External Internal connections Internal operating cab...

Страница 21: ...on the compressor the oil in the compressor crankcase must be heated before the first start Moment Done Note Stop the Supply and extract fan via the Topvex air handling units safety switch Turn on the...

Страница 22: ...or running Read the below values via the display of the frequency converter see section Frequency converter quick guide in Operating and Maintenance Instructions First set the parameter for reading th...

Страница 23: ...Topvex SoftCooler TR09 15 Installation instructions 208767 21 Systemair Sverige AB...

Страница 24: ...erves the right to make changes and improvements to the contents of this manual without prior notice Systemair Sverige AB Industriv gen 3 SE 739 30 Skinnskatteberg Sweden Phone 46 222 440 00 Fax 46 22...

Отзывы: