SystemAir Topvex FC Series Скачать руководство пользователя страница 15

Installation |

11

4.6

Mounting the sliding door kit

A sliding door kit for the inspection doors can be acquired as an accessory and can be mounted on the units. The kit is
installed according to below procedure.

Warning

The door handles are only intended to be used during the installation and service. Handles must be removed
before the unit is put into operation to ensure the required level of safety for the unit.

1 Hinges

Close the hatch with all 4 or 6 handles (depending on
model) and unscrew the 2 hinges.

2 Repeat procedure

Repeat on the other hatch.

3 Mount the wheels

Mount the wheels in the prepared threaded inserts on
the side of the inspection hatch with the enclosed
screws and washers.

4 Sliding door support rails

Mount the sliding door rails on each side of the unit.
Fasten it to the casing with screws in the prepared
threaded inserts.

151627 | A002

Содержание Topvex FC Series

Страница 1: ...Document in original language 151627 A002 Topvex FC Compact Air Handling Unit Installation instructions GB...

Страница 2: ...Systemair AB All rights reserved E OE Systemair AB reserves the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously...

Страница 3: ...re how to install 6 4 3 Condensation drain 7 4 4 Installing the unit 9 4 4 1 Installation procedure 10 4 5 Supply air sensor 10 4 6 Mounting the sliding door kit 11 4 7 Connections 13 4 7 1 Ducting 13...

Страница 4: ......

Страница 5: ...fety of machinery General principles for design Risk assessment and risk reduction EN 13857 Safety of machinery Safety distances to prevent hazard zones being reached by upper or lower limbs EN 60204...

Страница 6: ...er maintenance shall not be made by children without supervision 3 Product information 3 1 General This installation manual concerns air handling unit type Topvex FC manufactured by Systemair Sverige...

Страница 7: ...A D 70 70 E 148 I H G J K 137 98 98 L F A A A A A A 1 2 M Fig 1 Dimensions Topvex FC02 mm drawn as right hand unit male connection Model A B C D E F Topvex FC02 1500 2101 1919 1208 1577 1720 Model G...

Страница 8: ...098 2242 Topvex FC06 2214 2546 1182 1208 2288 2432 Model G H I J K L M Weight kg Topvex FC04 446 979 600 200 250x500 200 400 420 Topvex FC06 471 1073 671 250 300x600 300 500 510 3 2 2 Space required I...

Страница 9: ...orted in such a way that it is protected against physical damage that can harm panels handles display etc It should be covered so that dust rain and snow cannot enter and damage the unit and its compo...

Страница 10: ...ection doors downwards When choosing the location it should be kept in mind that the unit requires maintenance regularly and that the inspec tion doors should be easily accessible Leave free space for...

Страница 11: ...id On left hand units the positions of the connection are reversed See table 1 how the height H corresponds to different maximum negative pressures If the unit is mounted in a tight area that makes it...

Страница 12: ...8 Installation 2 185 H 32 mm G Fig 4 Drainage connection right hand unit Table 1 H mm Max Negative pressure Pa 65 300 951 600 135 1000 1 Normal conditions 151627 A002...

Страница 13: ...gned for ceiling installation Left and right connections are possible Fig 5 Installing position left hand unit Fig 6 Installing position right hand unit Table 2 Symbol description Symbol Description S...

Страница 14: ...the installation in accordance with local rules and regulations Install the unit with 0 3 lean towards drainage connections 2 Lift the unit in place 3 Connect the unit electrically to the mains power...

Страница 15: ...the unit is put into operation to ensure the required level of safety for the unit 1 Hinges Close the hatch with all 4 or 6 handles depending on model and unscrew the 2 hinges 2 Repeat procedure Repe...

Страница 16: ...e pushed toward the centre of the unit On ly one hatch at the time can be opened like this 7 Apply seal Apply the enclosed self adhesive seal strip to the in ner frame of the unit casing 8 Close hatch...

Страница 17: ...pply air 2 Fan extract air 3 Filter supply air 4 Filter extract air 5 Heat exchanger 6 Electrical connection box 7 Damper by pass outdoor air 8 Pressure transmitter supply air fan extract air filter 9...

Страница 18: ...oms via the duct system and also to reduce noise from the duct system it self installation of silencers before every inlet diffuser is recommended 4 7 4 Electrical connections components Danger Make s...

Страница 19: ...rmer 230 24V AC 3 Terminals for internal and external components 4 Terminals for internal wiring 5 Terminals for power supply to the unit 6 Contactor K2 On Off Pump control water HW units only not pre...

Страница 20: ...ence neutral 31 AI 1 Temperature sensor supply air 40 Agnd UI reference neutral 412 UAI 1 UDI 1 Pressure transmitter extract air 422 UAI 2 UDI 2 Pressure transmitter supply air 44 UAI 3 UDI 3 Frost pr...

Страница 21: ...3 or 60 61 62 63 TCP IP Exoline TCP IP Modbus TCP IP WEB TCP IP BACnet RS 485 connection Fig 11 TCP IP connection Connect the device to panel outlet or switch module depending on type of air handling...

Страница 22: ...its NaviPad has an easy to understand menu structure and contains 13 languages B A C F E D 3 m A B C c cD E F 153 221 40 3 59 4 77 5 3 2 4 8 2 Mounting control panel The NaviPad control panel with 3 m...

Страница 23: ...concerning additional external equipment such as valve actuators motorized dampers roof units wall grilles etc see technical catalogue and their enclosed instructions For electrical connections of ex...

Страница 24: ...Topvex FC Installation instructions 151627 en_GB 2018 10 11 A002 Systemair Sverige AB Industriv gen 3 SE 739 30 Skinnskatteberg Sweden Phone 46 222 440 00 Fax 46 222 440 99 www systemair com...

Отзывы: