UK Declaration of Conformity

We, the manufacturer

Manufacturer

Systemair Sverige AB

Address

Industrivägen 3

SE-73930 Skinskatteberg

Sweden

declare under our sole responsibility that the products

Type/Model

TFC-P, TFC-S

Identification

Serial numbers dating from 2022 and onwards

fulfils the relevant provisions of following directives and
standards

Supply of Machinery (Safety) Regulations 2008

EN ISO 12100:2010

Safety of machinery – General principles for design - Risk
assessment and risk reduction

EN ISO 13857:2019

Safety of machinery – Safety distances to prevent hazard
zones being reached by upper or lower limbs

EN 60204-1:2018

Safety of machinery – Electrical equipment of machines –
Part 1: General requirements

EN 60335-1:2012

Household and similar electrical appliances – Safety Part 1:
General requirements.

EN 60 335-2-80:2003

Household and similar electrical appliances – Safety – Part
2-80: Particular requirements for fans.

EN 50106:2008

Safety of household and similar appliances – Particular rules
for routine tests referring to appliances under the scope of
EN 60 335-1.

EN 60529:2014

Degrees of protection provided by enclosures (IP Code).

Electromagnetic Compatibility Regulations 2016

EN 62233:2008

Measurement methods for electromagnetic fields of
household appliances and similar apparatus with regard to
human exposure

EN 61000-6-2:2005

Electromagnetic compatibility (EMC) – Part 6-2: Generic
standards – Immunity for industrial environments.

The Restriction of the Use of Certain Hazardous
Substances in Electrical and Electronic Equipment
Regulations 2012

EN IEC 63000:2018

Technical documentation for the assessment of electrical and
electronic products with respect to the restriction of
hazardous substances

The Ecodesign for Energy-Related Products and Energy
Information (Amendment) (EU Exit) Regulations 2019

327/2011 Requirements for fans above 125W

1253/2014 Requirements for ventilation units above 30W

1254/2014 Requirements for energy labelling of residential
ventilation units

EN ISO 5801:2017

Fans – Performance testing using standardized airways.

EN 13142:2021

Ventilation for buildings – Components/Products for
residential ventilation – required and optional performance
characteristics.

Persons authorized to compile the technical file:

Stefan Lindberg

Technical Manager

This declaration relates exclusively to the machinery in the
state in which it was placed on the market and excludes
components which are added or operations carried out
subsequently by the final user.

Skinnskatteberg, Sweden 2022-05-05

Sofia Rask

Managing Director

29

Содержание TFC-P Roof fan EC

Страница 1: ...Installation Operation and Maintenance instruction EN TFC P Roof fan EC TFC S Roof fan EC...

Страница 2: ...5 3 Speed controller for EC motors 9 5 4 Motor protection for EC motors 9 6 Commissioning 9 6 1 To do before the commissioning 9 6 2 To do the commissioning 9 7 Operation 10 7 1 To start a product wit...

Страница 3: ...uct is used for transportation of clean or contami nated air with a maximum temperature of 60 C in continuous operation The product is intended for installation outdoors on commer cial and residential...

Страница 4: ...e The data on the name plate applies to standard air that is specified in the standard ISO5801 1 5 1 Type designation Product name TFC P TFC S Dimension 225 225 280 280 355 355 450 450 500 500 560 560...

Страница 5: ...adjacent area during all work on the product Make sure that you know how to stop the product quickly in an emergency Use applicable safety devices and personal protective equipment during all work on...

Страница 6: ...If you install the product with free suction or free dis charge it is necessary to install a protection grille Make sure that the safety distance agrees with the standard DIN EN ISO 13857 and the stan...

Страница 7: ...Release the lock by pulling the lever beside the lock Caution Keep fingers away from the back of the hinge The back of the hinge is a poten tial pinch point Note TFC 225 and TFC 280 have no handle Ho...

Страница 8: ...the roof in accordance with applicable building standards and connect the fan to a duct system Note Obey local laws and regulations for installation of the roof curb on the roof 7 Close the electrica...

Страница 9: ...the pressure setpoint Setpoint 1 The normal operation pressure setpoint Setpoint 2 The pressure setpoint during a secon dary operation mode 10 Press Down to go to T Band SA and set the tempera ture r...

Страница 10: ...nd press P to select the desired measuring range 1 0 1000 Pa 2 0 500 Pa 3 0 300 Pa 4 0 200 Pa 6 Press Down to go to K Factor and set the K factor de pending on your product size Refer to the table 1 K...

Страница 11: ...until the vibrations are decreased Continuous strong vibrations can cause damage to components Do not increase the fan speed to a higher rpm value than the maximum value that is given on the name pla...

Страница 12: ...ion manual for the installed speed controller 2 Set the installed safety switch in the OFF position 7 2 1 To stop the product in an emergency Set the installed safety switch in the OFF position 8 Main...

Страница 13: ...ons are classified as follows If a stable ambient temperature is higher than 30 C or lower than 10 C if the temperature changes are large or if very contaminated air is transported 8 2 To clean the pr...

Страница 14: ...e 9 The air output is not sufficient The fan impeller does not turn in the correct direction Make sure that the electrical connection is correctly done The electrical connection is not correctly done...

Страница 15: ...al blockage Remove the blockage Phase loss occurs If the motor is a 3 phase motor make sure that no phase is missing The motor does not rotate A component in the power supply is defective Do a check o...

Страница 16: ...ed at an approved disposal location for electrical and electronic equipment 10 1 To disassemble and discard the parts of the product 1 Disconnect and disassemble the product in the opposite sequence o...

Страница 17: ...re of transported air C 60 Sound pressure dB Refer to the data sheet in the online catalogue at www systemair com Corrosion class IP class Voltage current frequency enclosure class weight Refer to the...

Страница 18: ...Abbreviation in wiring diagram Cable colour RD Red YE Yellow BU Blue WH White GN Green BN Brown BK Black GR Grey GY Green Yellow 12 3 1 Wiring diagrams for TFC P fans TFC P fans 1 phase 230 V TFC P 2...

Страница 19: ...TF Us 13 14 2 ID1 ID2 GND GND A A B B 10 24VDC WH BU YE RD GND Us BK WH BN GN YE BN BU T24 24V 230V 2 1 4 3 PE L1 N PE L1 L1 L1 L2 L3 N NC COM N L2 PE BU BN GN YE N NC C 3 8 4 5 6 7 2 9 1 11 12 10 15...

Страница 20: ...16 TFC P 560 1 Safety switch 2 Aux contact Signal relay 3 24 V DC 4 0 10 V out 5 0 10 V out 6 Digital input 7 Digital input 8 Temperature 9 Modbus slave 10 Transformer 11 Connection box 12 Pressure co...

Страница 21: ...ection box 2 0 10 V DC Ext 3 Time 1 min 4 Safety switch 5 Motor 6 230 V 1 TFC S fans 1 phase 230 V TFC S 355 4 BK BU GN YE GN YE BU BN WH 1 WH 2 5 2 1 4 3 PE L N RSA RSB BN BU WH YE RD DC GN YE BN BU...

Страница 22: ...RD M L2 L1 GN YE L3 WH WH PE L1 L2 L3 NC COM GN YE BN BK GY PE L1 L2 L3 4 5 TFC S 560 1 Connection box 2 0 10 V DC Ext 3 Time 1 min 4 Alarm 5 Safety switch 6 ON OFF 7 Motor 8 230 V 1 12 3 3 Pressure...

Страница 23: ...as with higher pressure 7 Digital input D1 terminals 1 2 8 Input outdoor temperature sensor terminals TF TF 9 MODBUS interface terminals GND A B ID1 ID2 and jumper J1 12 3 4 Wiring diagrams for speed...

Страница 24: ...MTV 1 10 MTV 1 010 1 IN Vac 2 IN Vac 4 Out 5 Out 10V 0 10V GND 230V AC S 5EC FRQ MTP 10 GND 10V A 10V 0 10V GND EC Vent EC Vent IN RPM PWM IN 10V OUT PWN GND TACH optional 10V 0 10V PWM GND 22...

Страница 25: ...y NO Relay NC 10V 0 10V GND Din1 12 3 6 Wiring diagrams for demand control for EC motors EC Basic EC Basic T for temperature control EC Basic 230V AC 1 IN Vac 2 IN Vac 4 Out 5 GND 10V 0 10V GND EC Bas...

Страница 26: ...stem has 2 units The control board CB and the room unit RU Connect the fan to the control board and remove the internal potentiometer EC Vent IN RPM PWM IN 10V OUT PWN GND TACH optional 10V 0 10V PWM...

Страница 27: ...GND A D PT1000 24V N out N in L out L in IN3 IN2 IN2 A Mains supply 230 V 1 AC 10 A B Analogue sensor for example pressure sensor C Analogue sensor for example pressure sensor type PT1000 D Digital s...

Страница 28: ...Output minimum 0 10V Output maximum 0 10V PCA 1000D2 Pressure controller For constant air volume control CAV or variable air volume control VAV GND A GND 1 2 US US PCA 1000 6000D2 10 24 V DC p p V PI...

Страница 29: ...2 1 1 TFC P TFC S fan 2 Roof curb TG Note For more information about accessories refer to www systemair com or speak to Systemair technical support 27...

Страница 30: ...s IP Code Directive electromagnetic compatibility EMC 2014 30 EU EN 62233 2008 Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposur...

Страница 31: ...lations 2016 EN 62233 2008 Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure EN 61000 6 2 2005 Electromagnetic compatibility EM...

Страница 32: ...r AB reserves the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously agreed specifications Systemair Sverige AB In...

Отзывы: