Axial Fans
AW, AR

Installation and Operating Instructions

GB

Содержание AR 1000DS

Страница 1: ...Document in original language 004 Axial Fans AW AR Installation and Operating Instructions GB ...

Страница 2: ...temair AB All rights reserved E OE Systemair AB reserves the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously agreed specifications ...

Страница 3: ...3 5 1 Intended use 3 5 2 Incorrect use 3 5 3 Technical data 3 6 Name plate and type key 4 7 Installation 5 7 1 Installation positions 6 8 Electrical connection 7 8 1 Electrical connection accessories 11 8 2 Protecting the motor 11 8 3 Variable speed fans 11 9 Commissioning 12 10 Operation 12 11 Troubleshooting maintenance repair 12 11 1 Troubleshooting 13 11 2 Maintenance 14 12 Cleaning 15 13 Dein...

Страница 4: ......

Страница 5: ...ditions regulations and laws Abide by the system related conditions and requirements of the system manufacturer or plant constructor Safety elements may not be dismantled circumvented or deactivated Only use the fan in a flawless condition Provide generally prescribed electrical and mechanical protective devices During installation electrical connection commissioning troubleshooting and maintenanc...

Страница 6: ...on of the electrical system from live components at all terminals 2 Prevent reactivation 3 Test absence of voltage 4 Ground and short circuit 5 Cover or restrict adjacent live parts 3 Warranty For the assertion of warranty claims the products must be correctly connected and operated and used in accordance with the data sheets Further prerequisites are a completed maintenance plan with no gaps and ...

Страница 7: ...he effects of extreme heat or cold Hazard due to loss of function of the motor bearing Avoid storing for too long recommendation max 1 year Check that the motor bearing functions properly before installation 5 Description 5 1 Intended use Systemair axial fans of the series AR and AW are exclusively designed as a built in device for conveying air according to its technical data 5 2 Incorrect use In...

Страница 8: ...3 phased E2 2 poled controllable by frequency converter 1 phased E4 4 poled controllable by frequency converter 1 phased E6 6 poled controllable by frequency converter 1 phased DV 4 poled voltage controllable 3 phased DS 6 poled voltage controllable 3 phased EZ 2 poled voltage controllable 1 phased EV 4 poled voltage controllable 1 phased ES 6 poled voltage controllable 1 phased D4 4 poled control...

Страница 9: ...ions Ensure that the fan and all its components are undamaged Fit the fans in such a way that there is sufficient access for installation troubleshooting maintenance and repair Protect against dust and moisture when installing Ensure that the information on the name plates fan and motor matches up with the operating conditions Important Damage to the bearings or other parts of the fan can occur Do...

Страница 10: ...5876 AW 800D EC sileo 35879 AW 1000D EC sileo 35899 AW 400DV sileo Axial fan 34124 AW 400E4 sileo Axial fan 34125 AW 450DV sileo Axial fan 34126 AW 500DV sileo Axial fan 34131 AW 560DV sileo Axial fan 34134 AW 630DS sileo Axial fan 34138 AW 710DV sileo Axial fan 34140 AW 910DS sileo Axial fan 34157 AR 710E6 sileo Axial fan 34482 AR 710DV sileo Axial fan 34483 AR 710DS sileo Axial fan 34484 AR 910D...

Страница 11: ... with electronic devices such as EC motors frequency converters or uninterruptible power supplies UPS Table 3 Description of electrical connections of the following fans AW 200 EC sileo 35854 AW 250 EC sileo 35855 AW 300 EC sileo 35857 AW 350 EC sileo 35859 AW 400 EC sileo 35860 AW 450 EC sileo 35863 Wire no Connection Color Function assignment CON10 L black or brown Power supply see name plate fo...

Страница 12: ...8 Electrical connection Client side Max speed Adjustable speed 10V n max 1V n min 1V 0 Adjustable speed through PWM 1 10 KHz 100 PWM n max 10 PWM n min 10 0 Adjustable speed through potentiometer 004 ...

Страница 13: ...responds to 10 modulation level 10 V corresponds to 100 modulation level 2 8 GND GND connection of the controller interface 3 7 0 10 V PWM Analog input 1 set value 0 10 V Ri 100 kΩ adjustable curve only usable as alternative to 4 20 mA input SELV 4 10 V Voltage output 10 VDC 3 max 10 mA power supply for ext devices e g potentiometer SELV 5 20 V Voltage output 20 VDC 25 10 max 50 mA power supply fo...

Страница 14: ...pplied voltage 5 50 VDC disable bridge to GND or applied voltage 1 VDC reset function triggers software reset after a level change to 1 VDC SELV 8 DIN2 Digital input 2 Switching parameter sets 1 2 according to EEPROM setting the valid or used parameter set can be selected via bus or via digital input DIN2 Parameter set 1 pin open or applied voltage 5 50 VDC Parameter set 2 bridge to GND or applied...

Страница 15: ...tor cannot switch on again automatically after it has cooled down Motor lines and temperature monitor lines should be laid separately on principle Without thermal protection Use a motor protection switch Note Internally connected thermocontact no external connection feasible or necessary Warning Risk of injury because of sudden start up of the fan Thermost switches switch after triggering by exces...

Страница 16: ...on have been correctly performed Before switching the fan on check for externally visible damage and ensure that the protective equipment functions properly Inlet and outlet are free Cable glands are tight Safety devices have been fitted Commissioning of speed controlled fans Check the fan for vibrations at all normal operation speeds during commissioning Determine and evaluate vibrations on the h...

Страница 17: ...e line routing Flow regulators not or only partly open Check opening position on site Intake or pressure ducts are blocked Remove the blockage Grinding sounds when starting or operating the fan Check if the duct connections of the fan are strained Loosen the duct connections and realign it Thermal contacts resistors have triggered Impeller rotates in wrong direction Change direction of rotation sw...

Страница 18: ...Extreme operating conditions Activity Every six months Annually Quarterly Every six months Check the fan and its components for visible damage corrosion and contamination X X Check the impeller for damage and imbalance X X Check the condensate drain is working correctly X X Clean the fan ventilation system see 12 Cleaning page 15 X X Check the screwed connections for damages defects and check that...

Страница 19: ...e order of installation and electrical connection 14 Disposal Ensure material is recycled Observe national regulations The device and the transport packaging are predominantly made from recyclable raw materials Disassemble the fan into its components Separate the parts according to reusable material material groups to be disposed of metal plastics electrical parts etc 15 Commissioning Report Warra...

Страница 20: ...z Power kW Fan impeller speed rpm Measured data at commissioning Voltage V Temp of transported air C Current L1 A Fan impeller speed rpm Current L2 A Air volume Differential pressure not necessary for Jet fans Air volume m3 s Current L3 A Differential pressure Pa For single phase fans fill in line Current L1 A Δ Pressure between suction side and discharge of the fan If an air flow measurement is n...