3
4.1.1
Indicators
General alarm LED shows when any alarm has occurred. Alarm type is not specified.
It is not possible to acknowledge alarms from the SAVE LIGHT control panel. Please check SAVE TOUCH
control panel or contact your local technical service provider.
The filter change LED shows when filters have to be replaced.
Filters cannot be cleaned and must be changed as necessary. This is normally done 2–3 times per year
depending on the air pollution at the installation site.
4.1.2
To select airflow level
LEDs show current airflow level (figure 3, pos. 3).
• Press
button to increase the airflow.
• Press
button to decrease the airflow.
Off
Low
(Minimum)
Normal
High
Refresh
(Maximum)
Auto — flashing
slowly
The fan can be
set to
Off
by
activating
Manual Fan
Stop
function in
Service
menu.
Fan speed – 25%
Fan speed – 45%
Fan speed – 70%
Sets speed of
both supply and
extract air fans
to
Maximum
levels to replace
indoor air with a
fresh air in a
short period of
time.
The unit returns
to previously
active mode
after 1 hour
when in the
Refresh
mode.
Automatic
airflow control.
Available only
when
Week
Schedule
,
Demand
Control
functions are
active or
Fan
Control
setting
is set to
External
.
Note:
•
Minimum
and
Maximum
airflow can only be activated by a signal from an external source.
•
Auto
mode or
Manual Fan Stop
function can be enabled using the SAVE TOUCH control panel or a
mobile application.
• It is
not
recommended to set fan to
Off
in standard households. If manual fan stop is activated, the unit
should be provided with dampers in exhaust and fresh air ducts to avoid cold draught and risk of
condensation when the unit has been stopped.
4.1.3
To cancel sleep mode
Press any button to cancel the sleep mode. SAVE LIGHT returns to the sleep mode after 3 minutes of inactivity.
All control panel lights are off during sleep mode. The sleep mode is active from 9:00 PM to 7:00 AM (based on time of
the air handling unit).
4.1.4
To change control panel address (if more than one control panel is used)
If more than one SAVE LIGHT control panel is used, the address of other control panels must be changed.
Each control panel must have it’s own unique address number. No control panel should have the same address value to
function properly.
1. Push and hold
button for 10 seconds to see a current control panel address value.