background image

Models Available

SS2415ADAS Strobe with Sync•Circuit

SS241575ADAS Strobe with Sync•Circuit

MASS2415ADAS Sounder/Strobe with Sync•Circuit

MASS241575ADAS Sounder/Strobe with Sync•Circuit

SS24ADAS
Synchronized Strobes
with Sync•Circuit

© System Sensor 8/96

This document is not intended to be used for installation purposes.

A05-239-03

APPROVED

A Division of Pittway

3825 Ohio Avenue, St. Charles, IL 60174

1-800-SENSOR2 (736-7672), Fax 630-377-6495

http://www.systemsensor.com

The SS24ADAS Series

 Synchronized Strobes are crystal

controlled to flash at precisely one flash per second. When
power is applied to an indicating circuit controlled by one
controller, all SS24ADAS or MASS24ADAS series devices in
that zone will flash simultaneously. No synchronizing
modules or coded supplies are necessary. The strobes can
be used in any combination with other System Sensor
ADA strobes, ADA horn/strobes, and ADA speaker/
strobes.

The unique lens/reflector design maintains the UL 1971

light dispersement pattern while flashing at the ADA
minimum 1 flash per second. Available in red at 24 VDC,
the SS24ADAS strobes can be surface mounted directly to
a standard 4

 backbox or can be mounted to our semi-

flush plate for recessed electrical boxes. They are also
available in combination with System Sensor Multi-Alert™
horns for both visible and audible signaling.

Features

• Works on two wire circuit
• No synchronization module required
• Synchronized and unsynchronized strobes can be

combined on the same zone in any combination

• Patent pending Sync•Circuit™
• 24 VDC versions only
• 15 and 15/75 cd versions available
• Available with Multi-Alert™ Sounder
• Constant current draw over voltage range
• Stand alone strobe mounts to single gang box with

MP-SF plate

• ADA compliant, UL 1971 listed
• Installer easy plug-in terminal strip

on stand-alone strobe

Specifications

Input terminals:

18 – 12 AWG

Shipping Weight:

SS-ADA Strobes:

5 oz. (141g)

MASS-ADA
Horn/Strobes:

10.4 oz. (293g)

Operating

Temperature Range:

32

°

F to 120

°

F (0

°

C to 49

°

C)

Mounting:

Surface:

4

 

×

 4

 

×

 1

1

/

2

 standard backbox

(2

1

/

8

  recommended)

Semiflush:

4

 

×

 4

 

×

 1

1

/

2

 standard backbox

(2

1

/

8

 recommended) with

MP-SF semiflush mounting plate
(order separately)

Dimensions:

TOP

TOP

4

4

4

4

5

3

/

32

3

3

/

4

1

11

/

32

2

3

/

4

1

/

4

3

SS Series ADA

MASS Series ADA

Содержание SS24ADAS Series

Страница 1: ... minimum 1 flash per second Available in red at 24 VDC the SS24ADAS strobes can be surface mounted directly to a standard 4 backbox or can be mounted to our semi flush plate for recessed electrical boxes They are also available in combination with System Sensor Multi Alert horns for both visible and audible signaling Features Works on two wire circuit No synchronization module required Synchronize...

Страница 2: ...5 35 55 93 99 85 800 1000 Hz Alternating AC 34 46 43 58 92 98 85 2400 Interrupted AB 35 56 43 64 90 98 85 2400 Continuous C 38 59 46 73 94 104 85 1200 Interrupted B 23 33 27 41 91 101 82 Swept Frequency A 34 47 43 60 92 101 85 Fast Warble None 30 47 38 59 92 100 85 Multi Alert Sounder MA12 24EH Current mA Sound Output dBA Clips on DC Regulated FWR Unfiltered2 Average Peak UL dBA Ratings Available ...

Страница 3: ... off tab Horn Strobe Combination Strobe Only From panel or previous device To Next Device or EOL VDC VDC IN OUT IN OUT IN OUT IN OUT Standard Light Distribution Vertical Dispersion Horizontal Dispersion A polar light distribution in both horizontal and vertical directions is mandated for the strobes by the Standard UL 1971 for the Hearing Impaired with specific minimum intensity percentages as sho...

Страница 4: ...ricans with Disabilities Act requirements for visible signaling appliances Strobe shall operate at 24VDC from a regulated DC supply or full wave rectified unfiltered supply The signaling strobe shall be powered from a non coded power supply when powered with the horn or powered independently Visual signaling devices are to be installed in all non sleeping corridor and sleeping areas 110 cd only pe...

Отзывы: