PROTOUCH-WIDE MONITOR: user documentation - PRELIMINARY
DOC/PROTOUCH-WIDE_MONITOR; V0.2
DOC_PROTOUCH-WIDE_MONITOR_V0.3.docx
Seite 20 von 35
© 2019 Syslogic Datentechnik AG | All rights reserved
2.
Carefully remove the PC box
3.
Detach the cables to the display and touch
2.7.2
Re-assemble the device
To re-assemble the device, follow 2.7.1 in reverse order
2.7.3
Replace fuse
1.
Locate the fuse right behind the power connector
2.
Extract with tweezers and replace with same type (Littelfuse 452004.MRL)
2.7.4
Cleaning the glass front
For cleaning the glass front please use a soft cloth and a standard glass cleaning detergent.
When cleaning during operation it may happen that input signals are generated.
Prevent the system from unwanted and dangerous actions while the front is
being cleaned.
Make sure the device has cooled down to room temperature
Important
Note
Be careful not to tear the cables for display and touch