User Manual of SY6000-Z series Installation
Chapter 3 Installation
3.1 Installation site
:
In order to get good performance and long lifespan, the installation
site should meet the following conditions:
z
Good indoor ventilation.
z
Ambient temperature-10
~40
.
℃
℃
z
Humidity less than 90%RH, without dew.
z
Don’t install in the combustibles such as woods.
z
Avoid direct sunlight.
z
No combustible, explosive, corrosive gases and liquids.
z
No ash dust, oil dust, floatable fibers and metal particles.
z
Strong installation base, no vibration.
z
No electromagnetic interference.
3.2
★
Precautions:
1. The cabinet applies for injection equipment which is dragged by
general three-phase AC induction motor or inverter motor. Motor
insulation class is B or above.
2. General three phase induction motor, which is driven by the
cabinet, can not run in long term at low speed.
3. Capacitor, VDR and other RC absorbing devices are not allowed
to connect with output terminals of the cabinets.
4. If there are contactors between the cabinet and the motor, must
ensure that the cabinet doesn’t output when the contact switches,
otherwise the cabinet may be damaged.
5. Installation environment should be well ventilated.
6. The cabinet should be used derating if the altitude is higher
than1000 meters. Derate using 10% when the altitude rises 1500 meters.
7. Compare with running at power frequency, temperature rise and
noise of the motor will increase slightly when use the cabinet. This is