User Manual of SY6000-Z series Operation
Chapter 4 Operation
4.1 Switchover between power frequency and energy-saving
4.1.1 Running at energy-saving switching to power frequency
1. The cabinet runs at the state of energy-saving, and the indicator lights.
2. Turn off pump motor of moulding injection machine, and make sure
the motor has stopped.
3. Rotate changeover switch, the indicator of power frequency running
lights at this time, then the cabinet starts running at the state of power
frequency running.
4. Start main motor of moulding injection machine, and start normal
operation
4.1.2 Running at power frequency switching to energy saving
1. The cabinet runs at the state of power frequency, and the indicator of
power frequency running lights.
2. Turn off pump motor of moulding injection machine, and make sure
the motor has stopped.
3. Rotate changeover switch, the indicator of energy saving running
lights at this time, then the cabinet starts running at the state of energy
saving running.
4. Start main motor of moulding injection machine, and start normal
operation.
★
Key point:
Turn off the motor of moulding injection motor before switchover
between power frequency and energy saving running, then start switching
between power frequency and energy-saving.
8