User Manual of SY5000 series AC Drive Maintenance
~95~
Start to check after no displaying of the monitor and turning off of the main
circuit power indicator.
Inspection contents are as shown in Table 8-1
Table 8-1 Regualr inspection contents
Inspection items
Inspection contents
Abnormal countermeasures
Main circuit terminal, screw
of control circuit terminal
Loosening of screws,
or not
Tighten with a screwdriver
Heat sink
Dust or not
Use 4~6kg/cm
2
pressure dry
compressed air to blow off
PCB
Dust or not
Use 4~6kg/cm
2
pressure dry
compressed air to blow off
Cooling fan
Abnormal noise,
abnormal vibration, or
total running time up
to 20,000 hours.
Replace cooling fan
Power components
Dust or not
Use 4~6kg/cm
2
pressure dry
compressed air to blow off
Aluminium capacitor
Discoloring, off-flavor,
bubbling, or not
Replace aluminium capacitor
8.1.3 Daily maintenance
Operational lifespan of inverter electronic components are closely related to
using environment, using condition and maintenance situation. Lifespan of vulnerable
parts under normal using conditions are as shown in Table 8-2:
Table 8-2 Replacement time of inverter components
Component name
Lifespan
Cooling fan
2~3 years
Capacitor
4~5 years
PCB
5~8 years
Regular service conditions of above inverter components are:
1. Ambient temperature
:
annual average 30
℃。
2. Load factor
:
under 80%
3. Run time
:
below 12 hour/day
Users determine replacement period according to actual situation.
8.1.4 Storage
1. Store inverters in well-ventilated places, and avoid high temperature,
humidity and dustiness.
2. Long time storage will lead to deterioration of electrolytic capacitors. So
ensure connection the inverter to power supply at least once in two years. And
input voltage slowly raises rated value by the voltage regulator.
Содержание SY5000 series
Страница 1: ......
Страница 2: ......
Страница 4: ...User Manual of SY5000 series AC Drive Overview 1 2 Instruction of model no 1 3 Nameplate instruction ...
Страница 11: ...User Manual of SY5000 series AC Drive Installation Figure 2 2 a 11KW 160KW Figure 2 2 b 185KW ...
Страница 21: ...User Manual of SY5000 series AC Drive Wiring 19 Figure 3 2b Connection diagram of SY5000 G series 18 5KW ...
Страница 22: ...User Manual of SY5000 series AC Drive Wiring 20 Figure 3 3a Connection diagram of SY5000 P series 18 5KW ...
Страница 83: ...User Manual of SY5000 series AC Drive Parameter instrction 81 ...