User Manual of SY5000 series AC Drive Parameter instrction
~67~
E.g. as known in below figure, E-018 should set as
(
10101100
)
2,
namely
172.
When b-003 = 1, setting frequency of default step speed is determined by
panel potentiometer
(
b-004 = 0
)
or external potentiometer
(
b-004 = 5
)
, and
corresponding frequency values of other each step speed are determined by E-022 ~
E-028.
Accel /decel times of first step speed are determined by b-015 ~ b-021, and accel
/decel time of other each step speed is determined by the value of E-029.