User Manual of SY5000 series AC Drive Parameter instrction
~54~
b-002
Corresponding function
0
Jog command is disabled.
1~4
Selection terminal PI1
~
PI4. When selected terminal disconnects with COM,
jog operation is inenabled; when they are connected, jog operation is enabled.
When carry out jog operation, setting frequency is the value of b-027. accel and
decel at this moment is determined by b-028 ~b-030. For jog accel /decel mode,
linear type
(
b-028 = 0
)
and S-curve type
(
b-028 = 1
)
are optional.
5
Jog operation by control panel.
b-003 multi-step speed operation mode
b-003
Corresponding function
0
Multi-step speed operation is disabled.
1
Set a integer of 0~7
(
E-019 is low post
,
E-021 is high post
)
by three virance
of E-019
,
E-020
,
E-021.
0 corresponds to multi-step speed setting default speed, 1 corresponds to multi-
step speed setting 1, and so on.
Thereby setting output frequency is one of 8 multi-step speed setting
frequencies.
2
Firstly run for some time (the time is determined by E-014) at the frequency
which is set by E-022.
Secondly run for some time (the time is determined by E-015) at the frequency
which is set by E-023.
Thirdly run for some time (the time is determined by E-016) at the frequency
which is set by E-024.
After that, run for some time (the time is determined by E-017) at the frequency
which is set by E-025.
Finally stop at the frequency which is set by E-025.
Содержание SY5000 series
Страница 1: ......
Страница 2: ......
Страница 4: ...User Manual of SY5000 series AC Drive Overview 1 2 Instruction of model no 1 3 Nameplate instruction ...
Страница 11: ...User Manual of SY5000 series AC Drive Installation Figure 2 2 a 11KW 160KW Figure 2 2 b 185KW ...
Страница 21: ...User Manual of SY5000 series AC Drive Wiring 19 Figure 3 2b Connection diagram of SY5000 G series 18 5KW ...
Страница 22: ...User Manual of SY5000 series AC Drive Wiring 20 Figure 3 3a Connection diagram of SY5000 P series 18 5KW ...
Страница 83: ...User Manual of SY5000 series AC Drive Parameter instrction 81 ...