User Manual of SY5000 series AC Drive Parameter instrction
~38~
○
b-002
Jog
command
0: disabled;
1: jog command is controlled by
status of PI1-COM;
2: jog command is controlled by
status of PI2-COM;
3: jog command is controlled by
status of PI3-COM;
4: jog command is controlled by
status of PI4-COM;
5: enabled.
1
0
○
b-003
Multi-step
speed
command
0: disabled;
1: 8-step speed running according
to according to statuses of [E-019],
[E-020], [E-021];
2: single-cycle operation according
to frequency [E-022] ~ [E-025], then
maintain running at frequency of
[E-025];
3: recycle operation according to
frequency of [E-022] ~ [E-025]
1
0
○
b-004
Analog
voltage
input
command
0: disabled
;
1: analog voltage input setting
frequency is controlled by PI1-COM
status;
2: analog voltage input setting
frequency is controlled by PI2-COM
status;
3: analog voltage input setting
frequency is controlled by PI3-COM
status;
4: analog voltage input setting
frequency is controlled by PI4-COM
status;
5: set frequency according to analog
voltage input
1
0
Содержание SY5000 series
Страница 1: ......
Страница 2: ......
Страница 4: ...User Manual of SY5000 series AC Drive Overview 1 2 Instruction of model no 1 3 Nameplate instruction ...
Страница 11: ...User Manual of SY5000 series AC Drive Installation Figure 2 2 a 11KW 160KW Figure 2 2 b 185KW ...
Страница 21: ...User Manual of SY5000 series AC Drive Wiring 19 Figure 3 2b Connection diagram of SY5000 G series 18 5KW ...
Страница 22: ...User Manual of SY5000 series AC Drive Wiring 20 Figure 3 3a Connection diagram of SY5000 P series 18 5KW ...
Страница 83: ...User Manual of SY5000 series AC Drive Parameter instrction 81 ...