User Manual of SY5000 series AC Drive Keypad operation
~36~
3
Acess in parameter setting of extended function group,
display E-000
4
Keep pressing the key until display E-045
5
Display current setting value 380
6
Keep pressing the key until display 370
7
Temporarily store current setting value 370
(
V
)
into
memory unit, the inverter will run according to new
setting value, and new data will be lost when power off.
Store current setting value 370
(
V
)
into memory unit,
the inverter will run according to new setting value, and
new data will be saved even if power off.
8
4~7
When need set other parameters of E group, please
repeat above 4~7 steps.
Press the key of FNC
,
and return to direct display
mode
4.2.3 Frequency setting
There are various ways and methods for frequency setting of SY5000 series
inverter, their priority is as shown in Table 4-2.
Table 4-2 frequency setting method and priority
Priority
Signal name
Corresponding function
parameters
1
Jog operation
b-002
2
Multi-stage speed run
b-003
3
0~5V/0~10V input of analog
b-004
4
4~20mA input of analog
b-005
5
Operation panel potentiometer
b-006
6
Purse input
b-007
7
Setting frequency of panel
number
b-001
high
↓
low
Содержание SY5000 series
Страница 1: ......
Страница 2: ......
Страница 4: ...User Manual of SY5000 series AC Drive Overview 1 2 Instruction of model no 1 3 Nameplate instruction ...
Страница 11: ...User Manual of SY5000 series AC Drive Installation Figure 2 2 a 11KW 160KW Figure 2 2 b 185KW ...
Страница 21: ...User Manual of SY5000 series AC Drive Wiring 19 Figure 3 2b Connection diagram of SY5000 G series 18 5KW ...
Страница 22: ...User Manual of SY5000 series AC Drive Wiring 20 Figure 3 3a Connection diagram of SY5000 P series 18 5KW ...
Страница 83: ...User Manual of SY5000 series AC Drive Parameter instrction 81 ...