User Manual of SY5000 series AC Drive Keypad operation
~33~
4.1.3
Keypad operation
Function of keys is as shown in Table 4-1
Table 4-1 Function of keys
Key
Name
Function
Function
key
In the direct mode, click here to enter functional group option, and
click the key again to ruturn back direct display status.In the status
of parameter setting, click here to return previous status.
Up key
In the status of functional group, do selection operation to functional
group options (basic function b group, extended function E group,
PID adjustment P group, 485 communication R group).
In the status of function code, do upwards selection operation to
function code.
In the status of parameter value, do adding setting value operation
to parameter value.
When the inverter runs according to control panel direct setting
frequency, enter the setting status of b-000 parameter, click the key
to increase output frequency.
Down
key
In the status of functional group, do selection operation to functional
group options (basic function b group, extended function E group,
PID adjustment P group, 485 communication R group).
In the status of function code, do downwards selection operation to
function code.
In the status of parameter value, do subtracting setting value
operation to parameter value.
When the inverter runs according to control panel direct setting
frequency, enter the setting status of b-000 parameter, click the key
to decrease output frequency.
Set key
In the direct mode, click here to enter functional group option.
In other statuses, click here to confirm options or data, and store
setting data in E
2
PROM which can be stored for long.
Run key
It is the start command key when controlled by control panel.
Clicking and releasing the key to issue running commands, the
inverter will accelerates running according to setting acceleration
time.
Stop/
reset
key
It is the stop command key when controlled by control panel.
Clicking and releasing the key to issue stop commands, the inverter
will decelerates stop according to setting deceleration time.
Use the key to reset the inverter when it trips because of a fault.
Содержание SY5000 series
Страница 1: ......
Страница 2: ......
Страница 4: ...User Manual of SY5000 series AC Drive Overview 1 2 Instruction of model no 1 3 Nameplate instruction ...
Страница 11: ...User Manual of SY5000 series AC Drive Installation Figure 2 2 a 11KW 160KW Figure 2 2 b 185KW ...
Страница 21: ...User Manual of SY5000 series AC Drive Wiring 19 Figure 3 2b Connection diagram of SY5000 G series 18 5KW ...
Страница 22: ...User Manual of SY5000 series AC Drive Wiring 20 Figure 3 3a Connection diagram of SY5000 P series 18 5KW ...
Страница 83: ...User Manual of SY5000 series AC Drive Parameter instrction 81 ...