A : Auto send mode
Command
Format
STX + INS + {Mode} + BCC + END
Example #1 [01] + “A” + “xx”
H
+ [0D] (get)
Example #2 [01] + “A” + “3” + “xx”
H
+ [0D] (set)
Value
STX
[01]
INS
“A”
Mode
“0” Off auto send;
“1” protocol mode;
“2” Address ID mode;
“3” ASCII mode(default);
“4” Stop read tag;
“5” Protocol mode(no connect hold);
“6” ID mode(no connect hold);
“7” KEYBOARD mode(no connect hold);
“R” Get UID Reverse Setting;
“R1” UID Reverse(default);
“R0” UID not reverse;
“B” Get Send Battery Level Setting;
“B0” No Send Battery Level(default);
“B1” Send Battery Level;
BCC
“xx”
H
(In Hex format)
END
[0D]
Response
Format
STX + INS + Mode + BCC + END
Success
[02] + “A” + “3” + “xx”
H
+ [0D]
Value
STX
[02]
INS
“A”
Mode
“0” Off auto send;
“1” protocol mode;
“2” Address ID mode;
“3” ASCII mode(default);
“4” Stop read tag;
“5” Protocol mode(no connect hold);
“6” Address ID mode(no connect hold);
“7” ASCII mode(no connect hold);
“R1” UID Reverse(default);
“R0” UID not reverse;
“B0” No Send Battery Level(default);
“B1” Send Battery Level;
BCC
“xx”
H
(In Hex format)
END