3.5
Frost Protection
It is possible to permanently damage the pressure transducer if it is not protected from frost. Under these
conditions the pressures exerted by the expansion of freezing water can exceed the maximum burst pressure
of the transducer.
The following precautions should be taken when deploying in a climate where temperatures below 0°C will be
experienced:
•
Install below ground as close as possible to the pipeline;
•
Install insulation above and around the PipeMinder-S;
•
Do not install above ground without frost protection as necessary;
Devices damaged due to overpressure events, whether due to the expansion of freezing water or very high
water pressures, will not be replaced under warranty.