CLEANING GUIDELINES
PAGE
|
78
the Dew Point temperature in °F (or °C). The chiller’s temperature setpoint must be set above the dew
point temperature.
For example, if the air temperature is 85 °F (29 °C) and the relative humidity is 60%, then the dew point
temperature is 70 °F (21 °C). Adjust the chiller’s temperature setpoint to 72 °F (22 °C) to prevent
condensation from forming inside the laser.
Refer to the dew point temperature table within the prior section for a range of air temperature and relative
humidity values. Remember that the laser’s coolant temperature must be set above the dew point
temperatures shown in the chart, but should not exceed the environmental specifications located in the
Series 48 General Specifications within the Technical References section of this manual.
Debris or contaminants on the laser’s output coupler or external beam delivery components may affect
laser processing and lead to damage or failure of the optics and/or the laser. Carefully follow the steps
below to inspect and clean the optical components in the beam path. Before beginning the cleaning
process, read this entire section thoroughly to ensure that all cleaning materials are available and that each
step is completely understood.
Important Note: Exercise great care when handling infrared optics; they are much more fragile
than common glass materials. Optical surfaces and coatings are easily damaged by rough handling
and improper cleaning methods.
Cleaning guidelines
•
Wear latex gloves or finger cots (powder-free) to prevent contamination of optical surfaces by dirt
and skin oils.
•
Never handle optics with tools; always use gloved hands or fingers.
•
Hold optics by the outer edge; never touch the coated surface.
•
Always place optics lens on a tissue or suitable equivalent material for protection; never place
optics on hard or rough surfaces.
•
It may be necessary to use a cotton ball or fluffed cotton swab instead of a lens wipe to uniformly
clean the entire surface of small-diameter mounted optics.
•
Before using any cleaning agents, read Material Safety Data Sheets (MSDS) and observe all
necessary safety precautions.
Required cleaning materials
The table below lists the type and grade of materials required to properly clean optical surfaces.
Table 5-1 Required cleaning materials.
Содержание Novanta 48 Series
Страница 1: ...ENGINEERED BY SYNRAD 48 Series User Manual...
Страница 21: ...SERIES 48 1 LABEL LOCATIONS PAGE 21 Series 48 1 label locations Figure 2 1 Hazard label locations 48 1 example...
Страница 22: ...SERIES 48 2 LABEL LOCATIONS PAGE 22 Series 48 2 label locations Figure 2 2 Hazard label locations...
Страница 23: ...SERIES 48 5 LABEL LOCATIONS PAGE 23 Series 48 5 label locations Figure 2 3 Hazard label locations...
Страница 29: ...EUROPEAN UNION EU REQUIREMENTS ROHS COMPLIANCE PAGE 29 Figure 2 2 Declaration Document...
Страница 40: ...SETTING COOLANT TEMPERATURE PAGE 40 Table 4 1 Dew Point Table F temperatures...
Страница 63: ...MODEL 48 1 GENERAL SPECIFICATIONS CONTINUED PAGE 63 Model 48 1 general specifications continued...
Страница 65: ...MODEL 48 2 GENERAL SPECIFICATIONS CONTINUED PAGE 65 Model 48 2 general specifications continued...
Страница 69: ...TECHNICAL DRAWINGS PAGE 69 Figure 4 15 Model 48 2 package outline and mounting dimensions 2 of 2...
Страница 70: ...TECHNICAL DRAWINGS PAGE 70 Figure 4 16 Model 48 5 package outline and mounting dimensions...
Страница 71: ...TECHNICAL DRAWINGS PAGE 71 Figure 4 17 Model 48 1 packaging instructions...
Страница 72: ...TECHNICAL DRAWINGS PAGE 72 Figure 4 18 Model 48 2 packaging instructions...
Страница 73: ...TECHNICAL DRAWINGS PAGE 73 Figure 4 19 Model 48 5 packaging instructions...
Страница 74: ...TECHNICAL DRAWINGS PAGE 74 Figure 4 20 FLMK 1A 10W fan shroud packaging instructions...
Страница 82: ...OPERATIONAL FLOWCHART PAGE 82 Operational flowchart Figure 5 1 48 series operational flowchart...
Страница 85: ...STATUS LEDS PAGE 85 Status LEDs Table 5 3 48 series Input Output LED Status Signals...
Страница 88: ...INDEX This page is intentionally left blank...