OWNERS MANUAL

SENTRY

SYNEXIS SYSTEM

OWNERS MANUAL

www.synexis.com

+1 844-352-7680

Содержание Sentry

Страница 1: ...OWNERS MANUAL SENTRY SYNEXIS SYSTEM OWNERS MANUAL www synexis com 1 844 352 7680 ...

Страница 2: ...CX 08 Manufactured by LCD Lighting Inc WARNING Do not allow the device to become clogged with dust or other debris Check it regularly and replace the catalytic Sail or filter if they become clogged WARNING To reduce the risk of fire or electric shock do not use this product with any solid state speed control device When using an electrical device basic precautions should always be observed includi...

Страница 3: ...ource Disconnect power cord before opening cover 11 Do not sit on or place any object on this device 12 Do not use with a damaged power cord or plug If the power cord is damaged it must be replaced by Synexis its service agent or similarly qualified persons in order to avoid a hazard 13 Do not unplug the Sentry device by pulling on the power cord To unplug grasp the plug not the cord and remove fr...

Страница 4: ...y result in electric shock or fire 22 Do not use any cleaning agents or lubricants on the Sentry device Unplug power cord from outlet before performing any type of maintenance 23 To avoid a tripping hazard secure power cord when not in use 24 Do not use Sentry device near furnaces fireplaces stoves or other high temperature heat sources 25 Do not spray or apply perfumes directly on or near the fil...

Страница 5: ...Included Parts 6 About Synexis Dry Hydrogen Peroxide DHP 7 Indications for Use 7 Legal Notice 7 System Specifications 8 Installation 9 Troubleshooting 10 Maintenance 10 Getting the Most from Your DHP System 11 Warranty 12 ...

Страница 6: ...s and required tools Inspect your system and parts Please contact your Synexis Account Representative for questions or additional information Included Parts 1 Synexis Sentry device 2 Custom UV A Bulbs already installed 1 Filter Assembly x1 Carbon Filter x1 MERV 11 Filter 1 Power Cord 1 Owner s Manual After opening the box unpack and inspect your device for damage DO NOT OPERATE THIS DEVICE IF ANY ...

Страница 7: ...faces Because DHP is a true gas it can reach the toughest and most out of reach areas of your facility Dry Hydrogen Peroxide is effective because of its state of matter and method of action Indications for Use This product is not sold as a medical device and is not intended to be used to diagnose any disease or condition nor should it be used in the mitigation treatment or prevention of any diseas...

Страница 8: ...ments The Sentry can be mounted virtually anywhere and requires only a standard 120 VAC outlet Specifications Weight 42 lbs Material 18 Gauge Galvannealed Steel Color Black White Mounting Options Floor Shown Wall Mount Dimensions Width 17 43 2 cm Height 15 38 1 cm Depth 10 25 4 cm Electrical Requirements Input Voltage 120 VAC 60 Hz US Current 1 7 Amps 8 www synexis com 1 844 352 7680 17 10 17 10 1...

Страница 9: ...tter which direction the Sail is installed 4 To insert the filter cartridges open the smaller access plate towards the bottom of the device using a similar spring assisted latch The access plate should be completely removed while inserting or replacing the filter cartridges Insert the filter cartridges into the filter slot using the details below and the picture to the right The pleated MERV 11 fi...

Страница 10: ...ert it into the device The filters and Sail can be disposed of in regular trash or as recyclable fiber and plastic frame and polyester fabric No special handling conditions are required Sail Replacement First 7 14 days after first turning device on This is called the Control Phase and is when a Synexis System is first introduced to a new environment and level of bioburden Every 3 months once per q...

Страница 11: ...sed space so it is important to keep all external windows and doors closed as much as possible Open windows and or doors can significantly reduce the efficiency of your system by allowing the DHP to dissipate out of the facility Run your Synexis System 24 hours a day The Sentry is designed to operate 24 hours a day 7 days a week DHP is meant to be a continuous clean technology as opposed to a temp...

Страница 12: ... Representative for any device questions service material needs or device issues When contacting Synexis for a system issue that is under warranty please be prepared to provide the following A copy of the bill of sale Invoice or receipt of purchase An explanation of the problem or defect ...

Страница 13: ...13 www synexis com 1 844 352 7680 This page intentionally left blank ...

Страница 14: ...14 www synexis com 1 844 352 7680 This page intentionally left blank ...

Страница 15: ...15 www synexis com 1 844 352 7680 This page intentionally left blank ...

Страница 16: ...SYN GEN 0820 006 1 Synexis LLC 11711 W 79th St Lenexa KS 66214 1 844 352 7680 info synexis com ...