Introduction
PRX-20 card reader is a non-contact high performance card
reader with ABA (14 & 13 char), standard Wiegand 26 bits
and Wiegand 44 bits output format. These units are mainly
used as card reading support for access controllers and are
characterized by their smart and elegant appearance, simple
wiring and stable performance.
Specifications:
Type of cards
* Any card of 64bit memory array used by H4001 CMOS
integrated circuit, by EM Microelectronic-H4100/4102 or
compatible.
Clock & Data ABA
(14/13 char), standard Wiegand 26 bits and
Wiegand 44 bits output format interface, photo coupling seclusion
OC gate output.
RS-422
Differencial outputs:
Connection distance
up to 300m.
TTL outputs:
up to 15m.
Note
: In case of reading errors, 1K pullup resistors can be
added to the Data and Clock outputs (yellow and white
wires).
Operating state:
sound-visual state indication
Light Indications
Definition of Wires
Differential
Output format options
Wiegand Output Format - Further details
D0 and D1 output “0” and “1” respectively.
When outputting “0”, D0 experiences a negative pulse and
when outputting “1”, D1 experiences a negative pulse.
See the following diagram displaying a negative pulse width
of TP=100+10 microsecond; with a repetition period of
TW=1000+100 microsecond and 1 microsecond=1/1000000
a second.
In the following diagram C and O stand for 0 or 1.
E: even check code; O: odd check code
The three bytes in the middle of CCCC CCCC, CCCC
CCCC, CCCC CCCC are the swiped badge number, trans-
mitted from left (E) to right in sequence.
Dimensions
Model
Weight
L120x W45x H21 (mm)
PRX-20
300 g
Power supply
Operating Voltage: DC 5V-12V: Maxi-
mum Current Consumption: 80mA;
Ambient temperature
Operating temperature: -10C ~ +55C;
Storage temperature: -10C ~ +60C;
Humidity
Operating: 20%~98%; Storage:
5%~90%;
Available Output
format
Standard wiegand 44BIT; ABA Synel (14
char); ABA Linear (13 char)
Cable description
10 wires #24 wg (3 m.)
EM card*
reading distance: 80- 150mm (subject to
quality of the card)
Yellow light
standby state
green and red light
card reading status
Model: PRX-20
Indication
Color
Power on
Yellow
Ok indication
Green + 1 beep
activated by
controller
Error
indication
Red + 3 beeps
Wires color
Wiring Definition
Red
DC 5V-12V
Black
GND
Yellow
Data0/Data
White
Data1/Clock
Violet
Card Present
Brown
Green LED
Blue
Red LED
Green
Buzzer
Orange
Se1_EX Output Format wire #1
Gray
Se2_EX Output Format wire #2
Wires color
Wiring Definition
Red & Black
D0+ / Data+ ( RS-422 positive signal level)
White & Black
D0- / Data- ( RS-422 negative signal level)
Black & Green
D1+ / Clock+ ( RS-422 positive signal level)
Black & Yellow
D1- / Clock- (RS-422 negative signal level)
Se1_EX=1, Se2_EX=1
ABA Synel (14 char)
Se1_EX=0, Se2_EX=1
ABA Linear (13 char)
Se1_EX=0, Se2_EX=0
Std. Wiegand 26bits
Se1_EX=1, Se2_EX=0
Wiegand 44bits
Note:
1
. Se1_EX=1 or Se2_EX=1 is a free wire, not connected to
any wires.
2
. Se1_EX=0 or Se2_EX=0 is a wire connected with GND.