TECHNICAL DATASHEET

 

Sync DIN Rail Power Supply 

24V 50W 1 Phase (NEC Class 2) / DRS-24V50W1N

□ 

 

 

  

All parameters are specified at 25°C ambient and AC input unless otherwise indicated.

 

  www.DeltaPSU.com (December 2018, Rev. 03) 

 

1

 

 

Highlights & Features 

  Ultra-compact size and galvanic isolation up to 3.0KVac 

between input to output and input to ground 

  Universal AC input voltage and full power from -10°C to 

+55°C operation 

  Up to 90.0% efficiency 

  Low earth leakage current < 0.5mA @ 264Vac 

  Built-in DC OK relay contact option available 

  Extreme low temperature cold start at -40°C 

  NEC Class 2 / Limited Power Source (LPS) certified 

  Certified according to IEC/EN/UL 62368-1 

 

 

Safety Standards 

 

CB Certified for worldwide use 

 

 

Model Number:

   

DRS-24V50W1N

 

Unit Weight:

 

 

0.18 kg (0.40 lb) 

Dimensions (L x W x D):

  75 x 30 x 89.5

 

mm

 

(2.95 x 1.18 x 3.52 inch) 

 

 

General Description 

The ultra-compact and competitively priced Delta Sync DIN Rail DRS-24V50W1N

 power supply is designed for industrial applications 

requiring highly reliable power supply that must fit in a small space. The Sync series operates with universal AC input range and offers 

full power up to 55°C. The output is adjustable from 24-28 volts, and can support up to 3000 microfarads of load capacitance. A green 

LED indicates output is present. The design is certified according to IEC/EN/UL 60950-1, IEC/EN/UL 62368-1 Information Technology 

Equipment (ITE) and UL 508 Industrial Control Equipment (ICE). The series is also fully compliant with RoHS Directive 2011/65/EU for 

environmental protection. NEC Class 2 and Limited Power Source (LPS) approvals are available for this product. 

 

 

Model Information 

Sync DIN Rail Power Supply 

 

Model  Number

 

Input Voltage Range

 

Rated Output  Voltage

 

Rated Output  Current

 

DRS-24V50W1N

 

85-264Vac (120-375Vdc) 

24Vdc 

2.1A 

 

 

Model Numbering 

DR

 

S –

 

24V

 

50W 

1

 

N

 

 

DIN Rail 

Product Series 
S – Sync Series 

Output Voltage  50W series 

Single Phase  NEC Class 2  Z – Without DC OK Relay  

      Contact 
R – With DC OK Relay  

      Contact 

 

 

 

*This picture is for reference to DRS-24V50W series only. 

Содержание DRS-24V50W1N Series

Страница 1: ...24V50W1N power supply is designed for industrial applications requiring highly reliable power supply that must fit in a small space The Sync series operates with universal AC input range and offers f...

Страница 2: ...istics Nominal Output Voltage 24Vdc Factory Set Point Tolerance 24Vdc 2 Output Voltage Adjustment Range 24 28Vdc Output Current 2 1A 50W max Output Power 50W Line Regulation 0 5 85 264Vac 100 load Loa...

Страница 3: ...33 C Operating Humidity 5 to 95 RH Non Condensing Operating Altitude 0 to 2 000 Meters 6 560 ft Shock Test Non Operating IEC60068 2 27 Half Sine Wave 50G for a duration of 11ms 3 times per direction...

Страница 4: ...es Safety Entry Low Voltage SELV EN 60950 Electrical Safety TUV Bauart UL cUL recognized CB Scheme EN 60950 1 EN 62368 1 UL 60950 1 UL 62368 1 CSA C22 2 No 60950 1 File No E191395 IEC 60950 1 IEC 6236...

Страница 5: ...ria A1 2kV Surge IEC 61000 4 5 Level 3 Criteria A1 Common Mode3 2kV Differential Mode4 1kV Conducted IEC 61000 4 6 Level 3 Criteria A1 150kHz 80MHz 10Vrms Power Frequency Magnetic Fields IEC 61000 4 8...

Страница 6: ...N Rail Power Supply 24V 50W 1 Phase NEC Class 2 DRS 24V50W1N All parameters are specified at 25 C ambient and AC input unless otherwise indicated www DeltaPSU com December 2018 Rev 03 6 Block Diagram...

Страница 7: ...cember 2018 Rev 03 7 Device Description DRS 24V50W1NZ 1 Input terminal block connector 2 Output terminal block connector 3 DC voltage adjustment potentiometer 4 DC OK LED Green 5 Universal mounting sy...

Страница 8: ...24V50W1N All parameters are specified at 25 C ambient and AC input unless otherwise indicated www DeltaPSU com December 2018 Rev 03 8 Dimensions DRS 24V50W1NZ L x W x D 75 x 30 x 89 5 mm 2 95 x 1 18...

Страница 9: ...ntil the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition and require removal re application of input AC voltage in order to re...

Страница 10: ...ent convection cooling keep a distance of 40mm 1 57 inch above and 20mm 0 79 inch below the device as well as a lateral distance of 15mm 0 59 inch to other units In case the adjacent device is a heat...

Страница 11: ...0 to 90 of its final steady state set value Hold up Time Time between the collapse of the AC input voltage and the output falling to 95 of its steady state set value Inrush Current Inrush current is t...

Страница 12: ...its internal feedback circuit fails The output voltage shall not exceed its specifications defined on Page 3 under Protections Power supply will latch off and require removal re application of input A...

Страница 13: ...at any line voltage from 85 264Vac and set the PSU 1 and PSU 2 output voltage Step 2 Connect the power supply units PSU 1 and PSU 2 to Vin 1 Vin 2 respectively of the DRR 20N or 20A module shown on t...

Страница 14: ...bstances in electrical and electronic equipment This product conforms to this standard Attention Delta provides all information in the datasheets on an AS IS basis and does not offer any kind of warra...

Отзывы: