1.2 Power supply, phases and brake
1.2.1 Pinout Power Terminal
Important
The cable length for Main Power Supply (12-48 V) must not exceed 30 m.
Important
The motor and power cables must be twisted for EMC reasons.
Terminal
#
1
Phase A
2
Phase B
3
Phase C
4
Phase D - Brake output 0-48 V PWM
5
Ground
6
Main Power Supply 12-48 V
7
Optional Logic Ground *
8
Optional Logic Supply 12-24 V **
Hardware Manuals / SOMANET Node / SOMANET Node rev. E.1 /
Installation Guide / Wiring instructions
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.7. | Built 2021-04-13
4/17