Input current
Max. 6 mA (@24 VDC)
Test pulse toleration (OSSD pulses)
Max. 1 ms
Reverse voltage protected
Yes
Allowed discrepancy between digital inputs
100 ms
Safe brake output (SBC)
Number of digital outputs
2 (dual-channel safety output for one brake
system)
Max. output voltage
Servo drive main power supply (48 VDC)
Min. output voltage
0 V
Max. current.
1 A
Max. peak current.
4 A
Note
This PWM controlled brake is configured by
as the regular brake.
1.6.2.3 Block diagram
Simplified block diagram of SOMANET Node Safety:
Hardware Manuals / SOMANET Node / SOMANET Node rev. E.1
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.10.2 | Built 2021-07-06