3.1.9.1.15 0x1023 OS command
undefined
Name
Index:Sub Type
Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access
PDO
Mapping
Command
0x1023:1
OCTET_STRING(8) 64
0
readwrite
Name
Index:Sub Type
Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access
PDO
Mapping
Status
0x1023:2
USINT
8
0
readonly
(default)
0: last command completed, no errors, no reply.
1: last command completed, no errors, reply there.
2: last command completed, error, no reply.
3: last command completed, error, reply there.
100-200: indicates how much of the command has been executed (in %, 100 = 0%, 200 = 100%).
255: command is executing (if the percentage display is not supported).
Name
Index:Sub Type
Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access
PDO
Mapping
Response
0x1023:3
OCTET_STRING(8) 64
0
readonly
(default)
Byte 0: See SubIndex 2.
Byte 1: Unused.
2-n: Command specific response data.