3.1.5 Protection
3.1.5.1 Overview
This feature allows users to define limits for the following values:
Undervoltage
Overvoltage
Overcurrent
Once these limits are violated, an
and the drive is stopped.
Also, a limit for Overtemperature triggers the error but this value is not customizable.
The temperature of the core board and the inverter are also measured and the values are available through
objects 0x2030 (Core temperature) and 0x2031 (Drive temperature). The unit is given in m°C.
When the measured temperature approaches 95% of the permissible value, a warning is triggered in the
. When the measured temperature reaches the limit, an error is triggered and the drive is
stopped.
3.1.5.2 Usage
To set the value for user-defined protection limits, enter the value in the corresponding subitems of object
0x2006 Protection
Undervoltage: 0x2006:1, Unit given in V
Overvoltage: 0x2006:2, Unit given in V
Overcurrent: 0x2006:3, Unit given in mA
3.1.5.3 Parameters
Limits for Undervoltage, Overvoltage and Overcurrent.
The temperature measured on the Core board.
The temperature measured near the inverter.