Symmons SCOT SLC-6000 Series Скачать руководство пользователя страница 1

SCOT

®

/Metering

Model Numbers

SLC-6000 Series

Metering Lavatory Faucet

Operation & Maintenance Manual

Metering lavatory faucet features 4" centerset 

mount, 3/8" copper supply tubes and temperature 

limit stop. Vandal resistant 0.5 gpm (1.9 L/min) 

aerator limits water flow to a maximum of 0.25 gpc 

(0.95 L/cyl) @ 60 psi with a maximum 30 

second closing time. Faucet constructed from 

brass, plated in standard polished chrome 

finish. 

Specification

Compliance

Modifications

Note: 

Append appropriate -suffix to model number.

SLC-6000

SCOT Metering Lavatory Faucet

-DP

8" deck plate

-G 

Grid drain

-IPS

1/2" male IPS connections

-OFG

Offset grid strainer

-ASME A112.18.1/CSA B125.1
-NSF/ANSI 61.9, NSF/ANSI 372

Dimensions

Measurements

A

Ø 1-7/8", 48 mm

B

3-3/4", 95 mm

C

Deck Thickness Ref.

Min. 1/2", 13 mm

Max. 1", 25 mm

D

1-3/8", 35 mm

E

2-1/8", 54 mm

F

(2x) Hole Size

Ø 1/2", 13 mm

G

Hole Size

Ø 1-1/4", 32 mm

H

11", 279 mm

I

4", 102 mm

J

5-3/4", 146 mm

K

1-1/2", 38 mm

L

2-1/4", 57 mm

M

1-1/8", 29 mm

N

3-5/8", 92 mm

O

3/8", 10 mm

JJ

A

A

B

B

H

H

D

D

C

C

EE

G

G

II

K

K

LL

M

M

N

N

FF

O

O

TAPE

TAPE

Note: 

Dimensions subject to change without notice.

Limited Lifetime

 - to the original end 

purchaser in consumer/residential 

installations.

10 Years 

- for commercial/industrial

installations. Refer to 

www.symmons.com/warranty for 

complete warranty information.

Warranty

Содержание SCOT SLC-6000 Series

Страница 1: ...deck plate G Grid drain IPS 1 2 male IPS connections OFG Offset grid strainer ASME A112 18 1 CSA B125 1 NSF ANSI 61 9 NSF ANSI 372 Dimensions Measurements A Ø 1 7 8 48 mm B 3 3 4 95 mm C Deck Thickness Ref Min 1 2 13 mm Max 1 25 mm D 1 3 8 35 mm E 2 1 8 54 mm F 2x Hole Size Ø 1 2 13 mm G Hole Size Ø 1 1 4 32 mm H 11 279 mm I 4 102 mm J 5 3 4 146 mm K 1 1 2 38 mm L 2 1 4 57 mm M 1 1 8 29 mm N 3 5 8...

Страница 2: ...ession nuts U and ferrules V from supply stops Re tain for installation to faucet copper tubing Ensure washer is in place before installing Install check screen assemblies W to supply stops 2 Install faucet I threaded rods M mounting gasket Q and 3 8 cop per tubing P to deck surface M 1 3 R 2 S T 4 3 Place mounting brackets R and spacers S onto threaded rods M Secure hardware by tightening mountin...

Страница 3: ...1 2 1 2 D E F 3 G H 1 Faucet is factory set to shortest cycle time with 7 cycle timing washers C To increase time loosen set screw B remove handle A and remove one or more of the washers To reduce time add washers Reassemble faucet reversing above procedure MAXLINE THERMOSTATIC MIXING VALVE 8210CK COLD WATER BYPASS TEE FITTING SCOT FAUCET SLC 6000 TO HOT WATER SUPPLY DO NOT REMOVE TAPE TO COLD WAT...

Страница 4: ...unter Supply housing o rings worn Replace housing o rings G1 Faucet bleeding between hot and cold LL 71B check screens NOT in stalled Two chrome plated 3 8 check screens are supplied with every faucet and MUST be installed Faucet bleeding between hot and cold LL 71B check screens ARE in stalled Replace check springs K L Handle is loose Set screw has loosened Tighten set screw B Handle is sticking ...

Отзывы: