background image

Single Handle Pressure-Balancing Mixing Valve for Shower or Tub/Shower Application

INSTALLATION, OPERATION & SERVICE INSTRUCTIONS

NOTE: 2-1/2”  (64mm) min.

3” (76mm) max. On 2”x4” 

construction, use 2-1/2” 

(64mm) min. r ough-in.

Va lve inlets and outlets ar e 

1/2” (13mm) IPS connections.

5 5/8”

143mm

9 1/2”

240mm

approx.

24”

610mm

Symmons valves, shower heads and 

hand sprays comply to all known 

standards, codes and specifications: 

ASME A112.18.1/CSA B125.1, ASSE 

1016 etc. Symmons shower heads 

and hand sprays are equipped 

with a 2.5 gpm (9.5 L/min) water 

and energy saving flow restrictor.

This instruction sheet shows rough-in 
dimensions for Models 4-500VT(X),  
1-100VT(X) and 1-210VT(X). See sepa-
rate drawings enclosed with num-
bered models for applicable rough-in 
dimensions.
Tools required for installation of this 
product are: Phillips screw driver, 
tubing cutter, teflon tape, soldering 
equipment, adjustable wrench and 
channel-lock pliers.

Installation of Shower System 
Model 1-100VT(X) (Figure 2)

Install HOT on left and COLD on right 
according to valve markings.

1.  Install piping and fittings with valve 

body as shown in Figure 2 or 3. 
IMPORTANT: Valve rough-in is 2-1/2” 
(64mm) min. — 3” (76mm) max. from 
CENTERLINE OF SUPPLIES TO FACE 
OF FINISH WALL. Install so that surface 
indicated on plaster shield on valve 
is flush with finish wall as shown in 

Figure 1.

2.  When finishing tile wall REMOVE 

(pull off; don’t turn) ENTIRE PROTEC-
TIVE PLASTER SHIELD and FILL AREA 
AROUND VALVE BODY WITH GROUT 
OR PLASTER. DO NOT PLASTER OVER 
SC-2 CAP OR SERVICE STOPS IF SO 
EQUIPPED. 

3.  Turn on hot and cold supplies, valve 

will not operate unless both hot and 
cold water are turned on.

4.  This valve is equipped with a 

limit stop screw to be used to 
limit valve handle from being 
turned to excessively hot water 
discharge temperatures. To 
adjust, remove dome cover (SC-
13/18), place handle (VT-112) on 
stem, open valve to maximum 
desired temperature and turn in 
limit stop screw (SC-26) until it 
seats. WARNING: Failure to adjust 
the limit stop screw properly 

finish wall face

2

3" 76mm max.

64mm min.

1

2

''

supplies

C

L

plaster shield

4

1

4

''- 4  "

108mm

114mm

1

2

FIGURE 2

Model 1-100VT(X) Shower System

FIGURE 1

All floor to center dimensions optional. Concealed piping  and fittings not furnished by manufacturer.

For California Residents

WARNING:

 

This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.