XLi IEEE 1588 Clock
187
997-01510-03, Rev. C, 12/12/2006
2
5
1
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
4.
In the “Browse MIB” popup select the “maskPllSynthesizer” entry. In the “MIB Instance” field type 0.
In the “SNMP set value” field type 1. Click the “Set” button.
5.
Verify that a popup appears saying “Set has completed successfully”.
6.
Select the menu item “XLI->Configuration”. In the popup “xliconfig” verify that the “maskPllSynthe-
sizer” entry is set to “disabled”.
7.
In the “Browse MIB” popup select the “maskPllSynthesizer” entry. In the “MIB Instance” field type 0.
In the “SNMP set value” field type 2. Click the “Set” button.
8.
Verify that a popup appears saying “Set has completed successfully”.
9.
Select the menu item “XLI->Configuration”. In the popup “xliconfig” verify that the “maskPllSynthe-
sizer” entry is set to “enabled”.
10.
Repeat steps 4-9 in turn for each additional entry under systemFaultConfigMasks.
Trap Testing
1.
1. Perform an action to generate a trap.
2.
2. Select the menu item “Fault->Alarms”.
3.
3. Verify in the “All Alarms” popup that there is an entry of the form:
Normal Thu Mar 21: 14:30.09 192.168.11.218 XLI system trap:
[1] private.enterprises.trueTimeEnt.products.xli.alarmDataIpAddr.0 (IpAddress)
192.168.11.218
[2] private.enterprises.trueTimeEnt.products.xli.alarmDataTimeStamp.0 (OctetString):
HH:MM:Ss UTC
[3] private.enterprises.trueTimeEnt.products.xli.alarmDataCode.0 (Integer):
alarmPrimaryPower
[4] private.enterprises.trueTimeEnt.products.xli.alarmDataDescriptorStr.0
(OctetString): F73 S LP LL----PSR---