Retrieve Performance Monitoring
This command retrieves the performance monitoring data from the
TimeSource 3600. This data includes MTIE, TDEV, Phase 1S, and
Phase 1M. For current 24 hour data, MTIE, TDEV, and Phase 1S
data are grouped every 15 minutes. In addition, there are 7 daily
summaries of MTIE, TDEV, and Phase 1M. Each value type can be
retrieved for both span inputs A and B.
MTIE data includes the following time intervals in seconds: 1, 4,
10, 40, 100, 300, 900, 1800, 3600, 7200, 14400, 28800, and
86400.
TDEV data includes the following time intervals in seconds: 1, 2,
4, 8, 16, 32, 64, 128, 256, 512, and 1024.
Phase 1S data includes 900 seconds of phase values.
Phase 1M data includes 60 minutes of phase values.
The command format is:
RTRV-PM-EQPT:[<tid>]:SPAN-a:<ctag>::<montype>
,,,,,[<mondat>][<montm>];
Содержание TimeSource 3600
Страница 1: ...TimeSource 3600 GPS Primary Reference Source 097 72060 01 Issue 2 ...
Страница 4: ...4 TimeSource 3600 This page intentionally left blank ...
Страница 16: ...16 TimeSource 3600 This page intentionally left blank ...
Страница 59: ...3 Chapter Installation This chapter is the sequential order of procedures for installation and power up ...
Страница 120: ...120 TimeSource 3600 S S S S S S S S S S S S S S S S S S S S S S S S S S S S S This page intentionally left blank ...
Страница 121: ...4 Chapter TL1 Reference This chapter provides information for using the TL1 language ...
Страница 202: ...202 TimeSource 3600 S S S S S S S S S S S S S S S S S S S S S S S S S S S S S This page intentionally left blank ...
Страница 223: ...6 Chapter Specifications This chapter provides equipment specifications ...
Страница 247: ...Index ...