098-00172-000 Revision A – December, 2009
Chapter 4 CLI Commands
Show Commands
Log 000: 20:48:42 01/11/1970: Logs cleared
Log 001: 20:49:25 01/11/1970: FLL state change from Bridging to Fast FLL
Log 002: 20:49:26 01/11/1970: Exit alarm 2 - Bridging
Log 003: 01:36:00 11/02/2008: Time was 20:53:12 01/11/1970
Log 004: 01:45:49 11/02/2008: Enter alarm 4 - 10MHz LOS
Log 005: 01:45:51 11/02/2008: Exit alarm 4 - 10MHz LOS
show output
This command provides a summary of signal output settings.
Syntax:
show output
Example:
TP-500> show output
Response:
TP-500> show output
Output 1 type : 2.048 MHz Clock
Output 2 type : 1PPS
Output 3 type : 2.048 MHz Clock
Output 4 type : 2.048 MHz Clock
HDB3 : Enabled
Freerun output mode : on
Holdover output mode: on
1PPS offset : 2984 ns
1PPS pulse width : 100000000 ns
1PPS mode
: standard
show ptp
This command provides a summary of all PTP-related settings.
Syntax:
TP-500> show ptp
Response:
PTP Mode : Multicast
Client MAC address : 00:B0:AE:01:22:D5
Grand Master 1 IP : 10.1.0.2
Grand Master 2 IP : 0.0.0.0
Management IP : 0.0.0.0
Note
: For a given
alarm_num
, the event log will only generate log
entries when the
alarm_num
is set to
enable
.
Содержание TimeProvider 500
Страница 10: ...Table of Contents 10 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...
Страница 12: ...List of Figures 12 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...
Страница 122: ...122 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 Chapter 4 CLI Commands Show Commands ...
Страница 146: ...146 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 T1 Format ...
Страница 174: ...Index W W 174 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...