Issue 2: Sep 99
TMSL 097-44018-26
Page 65
COMMAND CODE: OPR-ACO-ALL
PURPOSE
OPERATE ALARM CUTOFF ALL
This command silences all current audible alarm signals and lights the green ACO lamp on the MIS card.
This command will be executed on all shelves.
INPUT FORMAT
OPR-ACO-ALL:[<tid>]:[<shelf>]:<ctag>;
EXAMPLE
Input:
OPR-ACO-ALL:::111;
Response:
SANJOSE-114 1997-12-08 15:04:13
M
111 COMPLD
;
This example, tagged as command 111, silences the audible alarms in the current system.
shelf
meaning
(null)
master shelf
E1
expansion shelf 1
E2
expansion shelf 2
E3
expansion shelf 3 (or remote shelf if equipped with a remote shelf instead of an
expansion shelf 3)