Issue 2: Sep 99
TMSL 097-44018-26
Page 61
COMMAND CODE: INIT-REG
PURPOSE
INITIALIZE REGISTER
This command resets the specified performance-monitoring storage registers (<montype>) on the speci-
fied equipment. These registers contain performance monitoring information accumulated in previous
intervals. After putting ports into service, it is recommended that this command be used to initialize the
performance-monitoring storage registers on those ports to avoid the possibility of invalid data.
INPUT FORMAT
INIT-REG:[<tid>]:<aid>:<ctag>::<montype>;
The parameter values in the table below are as follows:
a
= 1–2
c
= 2
e
= 2–4 (c > b)
b
= 1–2 or ALL
d
= 1–4 or ALL
f
= 1–11
aid
parameter
value
meaning
ALL
montype
ALL
all spans of all DCIM, MRC, & PSM cards
DCIM-a-b
montype
ALL
all montypes
BPV
bipolar violations register
CRC
cyclic redundancy check errors register
MRC-a-d[&&-e]
montype
ALL
all montypes
BPV
bipolar violations register
CRC
cyclic redundancy check errors register
PSM-f-d[&&-e]
montype
ALL
all montypes
BPV
bipolar violations register
CRC
cyclic redundancy check errors register
MTIE
MTIE performance monitoring register
PHASE1M
phase 1-minute register
SLIPS
slips register
TDEV
TDEV performance monitoring register