![Symmetricom TimeProvider 500 series Скачать руководство пользователя страница 59](http://html.mh-extra.com/html/symmetricom/timeprovider-500-series/timeprovider-500-series_reference-manual_1419598059.webp)
Issue 2: Sep 99
TMSL 097-44018-26
Page 59
COMMAND CODE: INIT-COM
PURPOSE
INITIALIZE COMMUNICATIONS
This command causes the data terminal ready (DTR) signal to drop for 5 seconds on any of the three com-
munication ports (1, 2, or 3). (If a port is provision for TERM1 [no DSR/DTR support], the command will
indicate completed but no action will occur.)
INPUT FORMAT
INIT-COM:[<tid>]:<aid>:<ctag>;
The values in the table below are as follows:
a
= 1–3 or ALL
EXAMPLE
Input:
INIT-COM::COM-2:110;
Response:
SANJOSE-114 1997-12-08 15:04:13
M
110 COMPLD
;
This example, tagged as command 110, drops the DTR signal for 5 seconds on port 2.
aid
meaning
COM-a
drops the DTR lead on the specified communication port