![Symmetricom TimeProvider 500 series Скачать руководство пользователя страница 44](http://html.mh-extra.com/html/symmetricom/timeprovider-500-series/timeprovider-500-series_reference-manual_1419598044.webp)
TMSL 097-44018-26
Issue 2: Sep 99
Page 44
COMMAND CODE: ED-SSM-EQPT
PURPOSE
EDIT SYNCHRONIZATION STATUS MESSAGE EQUIPMENT
This command assigns a quality level to the output signal(s) of an input card or the output signals of a
TOTA-M, EA10-M, EA20-M, GTI-17, or GTI-18 card. Also specified are the SSM trouble code to be sent
out during clock holdover, and whether to use the Sa4 through Sa8 bits of an E1 signal for SSM messag-
es. This command will be denied if the shelf is set for no SSM.
INPUT FORMAT
ED-SSM-EQPT:[<tid>]:<aid>:<ctag>::[<ssmmsg>][,[<ssmtc>]
[,[<ssmsa4>],[<ssmsa5>],[<ssmsa6>],[<ssmsa7>],[<ssmsa8>]]];
Notes:
1. Any parameter left blank causes no change to that parameter.
2. “Input” in the table below refers to any input card other than a DCIM card.
The parameter values in the table below are as follows:
a
= 1–2
b
= 1–12
parameter
value
for card
meaning
aid
DCIM-a
DCIM-T, DCIM-EA
Specified DCIM card
GTI-a
GTI-17, GTI-18
Specified GTI card
INPUT-a
Input card other
than DCIM
Specified input card
TO-b
TOTA-M, EA10-M,
EA20-M
Specified output card
ssmmsg
QL-DNU
DCIM-EA, EA10-M,
EA20-M, E1 Input
cards, GTI-18
Do not use for synchronization
QL-DUS
DCIM-T, T1 Input
cards, GTI-17,
TOTA-M
Do not use for synchronization
QL-NONE
DCIM-EA, DCIM-T,
EA10-M, EA20-M,
TOTA-M
SSM is not supported
QL-NORM
DCIM-EA, DCIM-T,
EA10-M, EA20-M,
TOTA-M
No quality level assigned; the incoming quality level message
will be used, along with equipment conditions, to determine
the output quality level message