COMMAND CODE: SET-ATTR-PORT
PURPOSE
SET ATTRIBUTE PORT
This command sets the notification code associated with the specified event. This attribute governs
whether the event is reported automatically. Alarmed events are reported automatically by the REPORT
ALARM message. Non-alarmed events are reported automatically by the REPORT EVT message.
INPUT FORMAT
SET-ATTR-PORT:[<tid>]:<aid>:<ctag>::<ntfcncde>,<condtype>;
The parameter values in the table below are as follows:
a
= 1–2
d
= 2–4 (d > c)
b
= 1–2 or ALL
e
= 1–11
c
= 1–4 or ALL
aid
ntfcncde
condtype
meaning
DCIM-a-b
CR, MJ, MN, NA, or
NR
AIS
alarm indication signal
BPV
bipolar violations
CRC
cyclic redundancy check errors
LOS
loss of signal
OOF
out of frame errors
ALL
all condtypes
MRC-a-
c[&&-d]
CR, MJ, MN, NA, or
NR
AIS
alarm indication signal
BPV
bipolar violations
CRC
cyclic redundancy check errors
FFREQ
fractional frequency threshold exceeded
LOS
loss of signal
OOF
out of frame errors
ALL
all condtypes