274
TimeProvider 2300/2700 User’s Guide
098-00564-000 Revision A3 – July, 2013
Appendix A System Messages
Message Provisioning
Message Provisioning
The TimeProvider 2300/2700 and its expansion shelves support logging of events
using syslog defined facility and severity codes and system defined facility codes as
follows:
Facility codes
4 Security/authorization messages
20 TimeProvider 2300/2700 Messages (events and alarms)
21 TimeProvider 2300/2700 Command History
22 TimeProvider 2300/2700 Messages (events and alarms)
Severity codes
2 (critical) Critical: critical conditions
3 (major) Error: error conditions
4 (minor) Warning: warning conditions
5 (event) Notice: normal but significant condition
The syslog message format is as follows:
Mmm dd hh:mm:ss
host_name Process-name AlarmID,Index,Severity, MsgText
Where:
Mmm = Month; dd = date; hh:mm:ss = system time
host_name = hostname
process-name = alarmd
AlarmID = 000 thru Max_AlarmID
Index = 0 thru 155
Severity = Event | Minor | Major | Critical (defined by severity code)
MsgText = (see tables)
Notes:
Severity codes 2, 3, and 4, are also indicated by the Alarm
LED(s) on the front panel.