097-93100-01 Revision C – February, 2010
TimeCreator 1000 User’s Guide 109
Chapter 5 Provisioning
Routine Operation Commands
Summary for the GPS Input
Number of standing system alarms
Currently selected TOD Source
System date and time
Uptime for the IMC
Clock operating mode for the IOC
Assigned asset tag
To display the system status, enter the following:
Type
show status
and press
Enter
.
Routine Operation Commands
This section describes the commands you use to perform the following routine
operations with the TimeCreator 1000:
Displaying alarms
Displaying events
Restarting the server IMC card
Displaying Alarms
The Show Log Alarm command displays some of the local alarms in the alarm log in
chronological order (first in - first out). This command also allows the user to display
a specified number of alarms from the beginning or end of the log file.
Example
Type
show log alarm
and press
Enter
.
Displaying Events
The Show Log Event command displays some of the local events in the event log in
chronological order (first in - first out). The event log contains the 1000 most recent
alarmed and non-alarmed events. This command also allows the user to display a
specified number of alarms from the beginning or end of the log file.
Example
Type
show log event
and press
Enter
.