72
TimeAnalyzer 7x00 User’s Guide
098-00208-000 Revision A – February, 2010
Chapter 3 Configuring
Recovering From Reset to TP5000 Factory Defaults
Example 1:
For a Grandmaster Clock ID of 00:B0:AE:FF:FE:00:00:06, GrandmasterIP address
of 192.168.1.11, and probe VLAN ID of 35:
TP5000>set ptp-probe ioc1-1 active-probe gm-clock-id
00:B0:AE:FF:FE:00:00:06 gm-ip 192.168.1.11 vlan-id 35
For a Grandmaster Clock ID of 00:B0:AE:FF:FE:00:00:06, GrandmasterIP address
of 192.168.1.11, and no VLAN:
TP5000> set ptp-probe ioc1-1 active-probe gm-clock-id
00:B0:AE:FF:FE:00:00:06 gm-ip 192.168.1.11 <
enter
>
Example 2:
For an interval of 0.25 seconds ( -2 ) on Port 1 of IOC1:
tp5000> set ptp-probe ioc1-1 active-probe interval -2
Example 3:
For a duration of 500 seconds on Port 1 of IOC1:
tp5000> set ptp-probe ioc1-1 active-probe duration 500
Level :
Config and Admin only
Recovering From Reset to TP5000 Factory Defaults
The TP5000 Grandmaster factory defaults are different than the initial settings for
theTP5000 probe module as part of the TimeAnalyzer 7x00. If the TP5000 is reset
to factory defaults, the TP5000 will return to the TP5000 Grandmaster defaults. The
following procedures must be used to return the TP5000 to the proper probe
settings.
Enabling the Probe Option on the TP5000
Provisioning TOD Source for TP5000 Probe Module
Provisioning the Reference Output for TimeWatch
Provisioning the 10MHz & 1PPS Outputs