12713140-003-2 Revision E.01 – January 2007
SSU-2000e Technical Reference 207
Chapter 3 ICS Command Reference
OUTPUT
OUTPUT
Use this command to view or set the status of Output modules.
Level 0
Not applicable
Level 1
OUTPUT [xAy]
If you do not provide a parameter, the status information for all output
modules in the unit displays. If you provide an output address, the status
and setup information for the specified output module displays.
Status Information: Output module status, selected clock, status for all
four clocks, redundant partner, output PQL value, and output port status
Setup Information: Framer type, zero suppression (On or Off), minimum
clock level, PLL mask (On or Off)
The alarm level is handled by the
command. The alarm
elevation time is handled by
command.
Example
SSU_2000->output
2001-05-24T18:29:00Z ID: SSU2000 Name: SSU_2000
OUT STA Clk Clk Stat Port Status 1 1 1 1 1 1 1 1 1 1 2
Loc# Sta Sel A B C D Rednt M/S Pql 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0
---- --- --- -------- ----- --- --- --------------------------------------
2A01 Ok A /Y/Y/Y/Y None 2 / / / / / / / / / / / / / / / / / / / /
2A02 Ok A /Y/Y/Y/Y None 2 / / / / / / / / / / / / / / / / / / / /
2A03 Ok A /Y/Y/Y/Y None 2 / / / / / / / / / / / / / / / / / / / /
2A04 Ok A /Y/Y/Y/Y None 2 / / / / / / / / / / / / / / / / / / / /
2A05 Ok A /Y/Y/Y/Y None 2 / / / / / / / / / / / / / / / / / / / /
2A08 Ok A /Y/Y/Y/Y None 2 / / / / / / / / / / / / / / / / / / / /
3A08 Ok A /Y/Y/Y/Y None 2 / / / / / / / / / / / / / / / / / / / /
3A11 Ok A /Y/Y/Y/Y 3A12 (S) 2 / / / / / / / / / / / / / / / / / / / /
3A12 Ok A /Y/Y/Y/Y 3A11 (M) 2 / / / / / / / / / / / / / / / / / / / /
1A06 Ok A /Y/Y/Y/N 1A07 (M) NA / / / / / / / / / / / / / / / / / / / /
1A07 Ok A /Y/Y/Y/N 1A06 (S) NA / / / / / / / / / / / / / / / / / / / /
Level 2
Same as Level 1 operation
Level 3
Same as Level 2 operation, with the following additions:
OUTPUT xAy {ESF|D4|CCS|CAS}
OUTPUT xAy-z[&&z] {E1|2048}
OUTPUT xAy-z[&&z] {ENABLE|DISABLE}
OUTPUT xAy LEVEL {ACQ|LOCK}
OUTPUT xAy BYPASS {ON|OFF}
OUTPUT xAy-z[&&z] {133FT|266FT|399FT|533FT|655FT}
OUTPUT xAy {CRC|ZS} {ON|OFF}
OUTPUT xAy SSM {ON|OFF}
OUTPUT xAy SSM {4|5|6|7|8}
OUTPUT xAy-z[&&z] DUTYCYCLE {63/37|50/50}
OUTPUT xAy-z[&&z] COMPENSATE {275ft|550ft|825ft|1100ft|1375ft|
1650ft|1925ft|2200ft}