Chapter 2 TL1 Reference
Set Communication Parameters
126
SSU-2000e Technical Reference
12713140-003-2 Revision E.01 – January 2007
Set Communication Parameters
This command allows you to set the parameters for the serial communications
ports. Use this command to choose between the ICS and TL1 command mode.
Syntax
SET-PRMTR-COMM:[tid]:[aid]:ctag::[baud],[echo],[eol], [mode],[tout];
Empty fields leave parameters unchanged.
Related Commands
Retrieve Communication Parameters
Parameter
Format
Description
aid
ALL
,
COML
,
COMA
,
COMB
,
TELNET
, or
TL1
Sets the parameters for the specified communications
port.
baud
19200|9600
|4800|2400
|1200
Sets the communications baud rate for the specified port.
echo
ON | OFF
Sets the unit to use full (On) or half duplex (Off).
eol
CR | LF |
CRLF
Sets the end-of-line character(s) sent by the unit .
mode
ASCII |
TL1
Sets the mode of communication.
tout
5 – 43200
| NEVER
Sets the inactivity timeout period in seconds.