Installing the SSU-2000
Handling Modules
80
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
1. Align the module card edges with the plastic card guides of the selected slot.
2. Slide the module into the shelf until it seats fully into its rear panel edge
connector.
3. Tighten the captive screws located at the top and bottom of the module front
panel.
4. Enable the module using either ICS or TL1 commands. The example
commands are for slot 3 in the main shelf.
ICS command:
Type
CONFIG 1A3 ENABLE
, then press
Enter
.
TL1 command:
ACT-MODULE::S1A3:123;
Exchanging a Module
Use this procedure to exchange one type of module with the same type or a
different type of module in the same slot. The example commands are for slot 3 in
the main shelf.
1. Connect to the SSU-2000 using one of the methods described in
, on page 88. The system prompts for a user
name.
2. Log in to the system using your user name and password.
3. Disable the module using either ICS or TL1 commands. The example
commands are for slot 3 in the main shelf.
ICS command:
Type
CONFIG 1A3 DISABLE
, then press
Enter
.
TL1 command:
DISC-MODULE::S1A3:123;
4. Loosen the captive screws located at the top and bottom of the module front
panel.
5. Pull up on the top extractor and down on the bottom extractor to unseat the
module from the connector on the backplane.
6. Slide the module out of the shelf.
Caution:
To avoid possible damage and intermittent failures, ensure
that you have completely inserted the module into the system and
that you have securely tightened the captive screws.
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...