SSU-2000 User’s Guide
75
Installing the SSU-2000
Connecting an SDU-2000 Expansion Shelf
Figure 2-10. SSU Interface (J8) Expansion Terminator
Connecting a Single SDU-2000 Expansion Shelf
To connect a single SDU-2000 to the SSU-2000 main shelf, use the following
procedure.
shows the wiring diagram for a single SDU-2000 installation.
1. Remove the Expansion Terminator (part number 12013040-000-0, if installed)
from J8 on the rear panel of the SSU-2000. Set the terminator aside for use in
step 3, below.
2. Attach one end of the Expansion Cable (part number 12013050-xxx-0; the xxx
indicates the length of the cable) to J8 on the rear panel of the SSU-2000.
3. Attach the other end of the Expansion Cable to either J17 or J15 on the rear
panel of the SDU-2000.
If you are installing only one SDU-2000, then attach the Expansion Terminator to
either J15 or J17, whichever is available.
4. Attach one end of the Backup Clock cable (part number 12013115-xxx-0; the
xxx indicates the length of the cable) to J9 on the rear panel of the SSU-2000.
5. Install a BNO tee connector (part number 551095-0001) on J16 on the rear
panel of the SDU-2000.
6. Attach the other end of the Backup Clock cable to the tee connector on J16.
7. Set the Clock Termination switch S2 to the 120 Ohms position.
8. Set the Shelf Address switch S1 to the 2 position.
Caution:
To avoid damage to the J9 connector or the BNO tee
connector, be sure to align its internal pins with the mating connector.
The tee connector does not rotate once it is installed. If J9 is
damaged, you will have to replace the entire shelf.
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...