Interactive Command Set
346
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
IONAME
Use this command to set an alias name for each input or output port.
Level 0
Not applicable
Level 1
IONAME [xAy]
Use this command to display a previously specified name
associated with each I/O port.
Example:
SSU_2000->ioname
2001-05-24T18:28:23Z ID: SSU2000 Name: SSU_2000
1A05-01 GPS Input
Level 2
Same as Level 1 operation
Level 3
Same as Level 2 operation, with the following additions:
IONAME xAy-z[&&z] {CLR|“io_port_name”}
Use this option to set a name associated with each I/O port. No
control characters are allowed. Multiple spaces between words
reduce to one blank character. The port alias can contain up to 20
characters.
Level 4
Same as Level 3 operation
Remarks
None
Related
None
Restrictions CLR is an operand, and cannot be used as an I/O port name.
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...