Interactive Command Set
344
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
GPS STATUS
Loc# Sta PhaseA PhaseB Pql UTC
------- --- -------- -------- --- ---
1A03-01 Ok
-143
-145
2
Yes
1A05-01 Ok
-149
-149
2
Yes
Level 2
Same as Level 1 operation
Level 3
Same as Level 2 operation, with the following additions:
INPUT xAy[-z] {ESF|D4|CCS|CAS|1MHZ|1.544MHZ|2.048MHZ|
5MHZ|10MHZ}
INPUT xAy[-z] {ZS|SSM|CRC}{ON|OFF}
INPUT xAy[-z] PRIORITY {0-10}
INPUT xAy[-z] {ENABLE|DISABLE}
INPUT xAy[-z] SSM {4|5|6|7|8}
INPUT xAy[-z] PQL {1-16}
INPUT xAy[-z] MTIE [{EL1|EL2|CL1|CL2}]{T10|T100|T1K|
T10K|T100K} value
INPUT xAy[-z] MTIE {PRS|DS1|G.811|G.823}
INPUT xAy[-1] GAIN {ON|OFF}
INPUT xAy[-z] CSFLT {HIGH|LOW|OFF}
INPUT xAy[-z] {LOS| AIS|OOF|BPV|CRC}{SET|CLR} value
INPUT xAy[-z] FREQ {A|B}{SET|CLR|TAU} value
Allows you to change the setting of a specified Input module.
Options are:
ESF|D4
Sets the T1 framing mode:
ESF or D4
.
CCS|CAS
Sets the E1 framing mode: CCS or CAS
.
1MHZ|1.544MHZ|2.048MHZ|5MHZ|10MHZ
Sets the Input module clock frequency when input is not
running in framing mode. Only the clock frequencies
shown are valid. If the module is a framed T1 signal, the
CLK rate is 1.544MHz; if it is a framed E1 signal, the
CLK rate is 2.048MHz automatically.
ZS {ON|OFF}
Enables or disables Zero Suppression
For DS1: On = B8ZS, Off = AMI
For E1: On = HDB3, Off = AMI
SSM {ON|OFF}
Enables or disables Sync Status Message reading
CRC {ON|OFF}
Enables or disables CRC checking
PRIORITY {0-10}
Sets Input priority level, where: 0 = monitor,
1 = highest priority, and 10 = lowest priority
ENABLE
Enables the specified input port
DISABLE
Disables the specified input port. This clears all alarms
associated with an input and disables setting of further
alarms or use of the input measurements.
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...