12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 343
Interactive Command Set
INPUT
Use this command to access to the input status, hardware configuration, and alarm
settings.
Level 0
Not applicable
Level 1
INPUT [xAy[-z]][STATUS|SETUP]
If you do not provide a parameter, the command displays all the
input module status information in the unit. If a specified input
address is provided, that input status and setup information
appears.
Options are:
STATUS
Use this command to display input status information.
SETUP
Use this command to display input setup information.
Status information: status, phase A/B values, PQL, hardware alarm
(LOS, AIS, OOF, BPV, CRC) statuses, MTIE status.
Setup information: port (Enable or Disable), framed signal (D4 or
ESF if DS1, CAS or CCS if E1), unframed signal (if specified as
CLK), zero suppression (ON or OFF), CRC (ON or OFF), SSM (ON
or OFF), PQL provision value (1-16), priority (0-10), high gain (ON
or OFF), cesium fault indication level (High, Low, OFF), MTIE mask
limits, hardware alarm (LOS, AIS, OOF, BPV, CRC) error count and
clear error count setting.
If E1: SSM bit position (4 through 8)
The alarm level and delay time are handled by the ALARM
command. The alarm elevation time is handled by the ELEVTIME
command.
Example:
S>input
2001-07-16T12:57:14Z ID: SSU2000 Name: SSU_2000
INPUT STATUS L A O B C
O I O P R -MTIE1- -MTIE2- FREQ
Loc# Sta PhaseA PhaseB Pql S S F V C A B A B A B
------- --- -------- -------- --- --------- ---- ---- ---- ---- --- ---
1A04-01 Dis NA NA 4 / / / / Ok Ok Ok Ok Ok Ok
1A04-02 Dis NA NA 4 / / / / Ok Ok Ok Ok Ok Ok
1A04-03 Dis NA NA 4 / / / / Ok Ok Ok Ok Ok Ok
1A06-01 Sel -1 -2 4 / / / / Ok Ok Ok Ok Ok Ok
1A06-02 Dis NA NA 4 / / / / Ok Ok Ok Ok Ok Ok
1A06-03 Dis NA NA 4 / / / / Ok Ok Ok Ok Ok Ok
1A08-01 Dis NA NA 4 / / / / Ok Ok Ok Ok Ok Ok
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...