12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 307
TL1 Command Interface
SET-PRMTR-CLKOUT:[tid]:[aid]
:ctag::[pstate],[mode],
[level],[bypass],[fltmode];
Valid aid code:
ALL
,
SxA[y[-z]]
pstate
= sets output port state: [ON|OFF]
mode
= ignored
level
= set the clock mode: [WARM|ACQ|LOCK]
bypass
= allow Clock C selection [ON|OFF] when outputs
are turned on
fltmode
= allow output level to be monitored for fault
thresholds: [OFF|ON|AUTO]. Omitting the port aid (no
-z
in the aid sets all ports on the module to [ON|OFF].
Empty fields leave parameters unchanged.
SET-PRMTR-COMM:[tid]:[aid]:
ctag::[baud],[echo],[eol],
[mode],[tout];
Valid aid code:
ALL
,
COML
,
COMA
,
COMB
,
TELNET
, or
TL1
where:
aid
= set the communication port [ALL|COML|COMA|
COMB]
baud
= set the communications baud rate [19200|9600|
4800|2400|1200]
echo
= set unit to use full or half duplex [ON |OFF]
eol
= set end-of-line character(s) sent by the unit [CR| LF|
CRLF]
mode
= set the mode of communication to [ASCII|TL1]
tout
= set the inactivity timeout period [5 – 43200| NEVER]
SET-PRMTR-ELTIME:[tid]:[aid]
:ctag::elevtime;
Valid aid code:
SxAy
This command sets the time for alarm elevation, from 60
seconds to 500,000 seconds. A setting of 0 (zero) means no
elevation for the alarm. When an alarm has been at MINOR
or MAJOR level continuously for ELTIME seconds, then it is
elevated to the next level.
This may be set for each module or ALL modules, and
applies to all alarms created by the module.
SET-PRMTR-FREQ:[tid]:[aid]:
ctag::[fae],[fac],[fbe],
[fbc];
Valid aid code:
ALL
,
S1Ay[-z]
This command sets the input Frequency alarm thresholds.
fae
= error threshold for input versus A clock
fac
= clear threshold for input versus Clock A
fbe
= error threshold for input versus B clock
fbc
= clear threshold for input versus Clock B, for the
designated input
The maximum settings for these limits is 10 000 000 in units
of ps/s. Empty fields are unchanged.
SET-PRMTR-GPS:[tid]:[aid]:
ctag::pri],[pql],[sigma];
Valid aid code:
S1A3
or
S1A5
(for a unit with GPS module)
pri
= set the priority setting of [0 through 10, with 0 = MON]
pql
= set the priority quality level [1 through 16]
sigma
= set the limit of the noise measurement
[10 to 1000
µ
s]
Table B-6. TL1 Set Commands (Continued)
Command
Description
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...