TL1 Command Interface
266
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
TL1 Command Interface
Telcordia Technologies (formerly Bellcore) specifies the TL1 command interface for
use as a standard man-machine language for controlling telecommunications
network elements. TL1 provides command sets to support all operation,
administration, maintenance, and provisioning tasks required to maintain and
control an SSU-2000. These tasks include configuring and provisioning security,
monitoring system performance, configuring hardware, locating and handling faults,
and performing equipment diagnosis and testing.
To set up an SSU-2000 port for TL1 communications:
1. Log on to one of the SSU-2000 EIA-232 serial ports using a Supervisor-level (or
higher) user name and password.
2. Set port A, B, or L to TL1 mode. For example, to set the local port (COML) to TL1
mode, at the system prompt, type:
COMM L MODE TL1
The communications mode settings for the COMM A and COMM B ports (located
on the rear panel) are stored in non-volatile RAM, and remain in effect even after
restarting the SSU-2000.
Table B-2. Communications Module Software Versions
Part Number
Version
TL1
ICS
NTP
SNMP
v2
SNMP
v3
24113012-000-0
Basic System Load
X
X
24113012-001-0
Basic w/NTP Support
X
X
X
24113012-002-0
Basic w/SNMP v2 Support
X
X
X
24113012-003-0
Basic w/SNMP v2 and NTP
Support
X
X
X
X
24113012-004-0
Basic w/SNMP v3 Support
X
X
X
24113012-005-0
Basic w/SNMP v3 and NTP
Support
X
X
X
X
Note:
To communicate with the SSU-2000, you must first connect a
terminal to one of the three EIA-232-C serial communication ports
and then provision the Ethernet port (see
, on page 90). Then you can communicate with the
SSU-2000 using an Ethernet telnet session.
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...