![Symbol M2004-I418 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/symbol/m2004-i418/m2004-i418_special-operating-instructions_1419136011.webp)
M2004-I418 Special Operating Instructions
(73-39696-418)
Revision A: February 2004
11
Plural Stage Inter-Decode Wait Time
When a bar code from a plural stage set is
decoded, this parameter sets the amount of
time within which an attempt is made to
decode the next plural stage bar code within
the set. If another bar code is not decoded
before this time expires, the previous
decode(s) is invalidated.
To select a new wait time (programmable from
0.0 to 5.0 seconds in .1 second increments),
scan the bar code below followed by two
numeric bar codes, starting on
.
Plural Stage Inter-decode Wait Time
Plural Stage Decode Inhibit Timeout
Between Full Stage Decodes
This parameter sets the amount of time the
scanner delays before resuming decode
attempts after a complete stage has been
decoded (i.e., all rows have been read).
To set this parameter (programmable from 0.0
to 5.0 seconds in .1 second increments), scan
the bar code below followed by two numeric
bar codes, starting on
Plural Stage Decode Inhibit Timeout